Power Pak Series 3 Generator Installation Instructions
9 Outside Room Digital Timer Installation
NOTE
DO NOT mount inside the steam room.
1. Outside of the steam room door, install the digital timer device. This allows the generator, when the room is not
occupied, to reduce the room tempature and save energy, and when a user activates it, it will produce steam to the
set temearture of the master control.
Note: After installation, you can override the timer with the main control panel. See pg. 12.
2. Run the yellow M8 50' wire provided with the digital timer through conduit. Connect the M8 wire to the back of the
digital timer device and the other end to the power pak.
3. Attach the 60-minute timer attach lead connections to the timer. Using the supplied screws with the timer box, screw
the timer onto the single gang box.
4. Do not staple timer cable.
Failure to follow installation instructions may cause the warranty to be void.