Installation Guide
Doc. No: 81128 Page 13 of 16 Rev G 1/17
JWJ
Controller Notes and Tips
The system will revert back to displaying the current time and day after 1 minute of no
button activity. The SET button is used to select between various display sets.
The ALL day feature is extremely useful as it give an ability to quickly set start, stop, and
power clean times for all days. Then on days such as weekend days, the user can modify
only those days eliminating the need to enter redundant information.
The system is equipped with usage odometer embedded in a special diagnostics menu.
Pressing and holding the SET button for 5 seconds, will show the current firmware
version of the control, this feature is important for customer service support. After 2
seconds, the display will show the total hours the generator was on (heater on) in 10-hour
increments. This number would help service the unit more efficiently as it will provide
usage/time information.
The start, stop, and power clean times are related to each other automatically. The
system is shipped from the factory with default values of 7:00 start, 20:00 stop, and 23:00
power clean for all 7 days. The user can always revert (reset) back to these original
defaults by pressing and holding the UP and DOWN buttons simultaneously for 5
seconds.
If the start time reaches the stop time, the system will automatically fix that by pushing
the stop time forward. Similarly, if stop reached start, it will attempt to push start
backwards if possible until reaching 00:00. If both times will reach 5 minutes of power
clean, the system will try to jump over 50 minutes after power clean, if it is unsuccessful, I
will remain in previous setting.
The system supports temperature in both Fahrenheit and Celsius with a default factory
setting of Fahrenheit. To change the units to Celsius, press the set button until you reach
Temperature menu, and then press and hold the DAY button for 5 seconds and release.
The system will toggle between units every 5 seconds while DAY button is depressed.
The MANUAL button enables operation without timing constrains set by start, stop, and
power clean cycle. Pressing MANUAL will be marked by Manual mode red LED, turn on
the generator and cancel power clean cycle. Automatic On and Off event will not control
the generator. To cancel this mode, press the MANUAL button once again; the red LED
will light next to Auto.
The PAUSE button will halt the generator from producing steam. Pause mode will be
marked by a red LED next to PAUSE. To resume regular operation, Press once again on
PAUSE.
The system is equipped with a self-diagnostics error messaging system. Upon a system
malfunction, an error message will be displayed with the following code numbers:
Err 0 - General Code Error
Err 1 - Pause button stuck
Err 2 - Up button stuck
Err 3 - Down button stuck
Err 4 - Set button stuck
Err 5 - Float switch tripped for 10 seconds
Err 6 - Max heat exceeded
Err 7 - Day button stuck
Err 8 - Manual button stuck
Err 9 - Temperature sensor is disconnected
or not functioning
** AFTER PROGRAMMING** To have the unit steam immediately, press the
MANUAL button once.