Installation Guide

Doc. No: 81128 Page 11 of 16 Rev G 1/17
JWJ
ThermaSol PowerPak Series
Control Operating Instructions
1. Ensure electrical/plumbing installation is complete (see page 7,
note 6) turn on power to unit at the breaker. You will see a
message SET CLOC that means a valid time has to be set prior
to any operation. To proceed, press DAY button once. The
display will change to 00:00 and the day will blink Sunday. Wait 5
seconds. After 5 seconds, the system will accept this as the valid
time. To set the correct time, use the UP or DOWN to adjust the
time. Press DAY until you reach the correct day of week. Wait 5
seconds. After 5 second, the display will now show the time and
day of the week. The time displayed is a 24-hour clock while the
day of week of marked by an led next to the DAY label.
2. Now you will set the “Steam Start Time”. Press the SET button
once. You should see the light next to the “Start Time” come on
and red light next to ALL day. The ALL feature sets the start time
for all 7 days. This saves time on entering redundant information
7 times. Using the DAY button, you can individually change the
start time of a specific day. The system comes from the factory
with default values of 7:00 start time for all seven days. Using the
arrows set the time you want the steam to begin on that day from
now onward.
3. Next, set the “Steam Stop Time” using similar way as the Start
Time. Press the SET button once. You should see the light next
to the “Stop Time”. Using the arrows set the time you want the
steam to stop for that day from now onward. Note that you are
either programming a specific day or ALL (1 week). If ALL was
the day configured, the settings will be applied to all 7 days. If
there is a need to modify specific days, press DAY to move to the
desired day to modify the time.
4. Pressing the SET button will let you see the current steam room
temperature, and also enable you to configure the Temperature
Set Point. Upon a first press of UP or DOWN, the set point will be
displayed. Using the arrows set the temperature you want to be
stored as the Set Point. This Generator will use this temperature
as a threshold for turning on and off while keeping the steam
room at constant desired temperature. This temperature is
applied to all 7 days a week. After programming, to have the unit
steam immediately, press the MANUAL button once.