Installation Guide

81098 Page 8 of 21 REV K 02/17 JWJ
Electrical Installation
Note: All electrical wiring must be done per National/Local Electrical Codes.
** ThermaSol requires that a licensed electrician perform all electrical work. **
Note: USE COPPER WIRE ONLY.
Wire sizes recommended by NEC (2002 Version). Minimum wire temperature rating 90C. Type THHN.
Generator Model
Phase
Wire
Gauge
Breaker
Size
Factory Sized
Cu Ft MAX
AMP draw @
240-VAC
KW
Day Spa 150
1
8
50A
150
46A
10KW
Day Spa 250
1
6
60A
250
56A
12KW
Day Spa 400
1
8/8
40/40A
400
37/37A
16KW
Day Spa 650
1
8/8
50/50A
650
46/46A
20KW
Electrical Questions? (800) 776-0711 for Technical Support
Warning: Each generator should be wired to their own separate breaker.
1. Turn off all electricity to the working area at the main breaker panel!
2. Connect 208/240VAC electrical lines to wires labeled 1 & 2 (for DS-150, DS-250) 1, 2, 3, 4, (for
DS-400, DS-650) located in the electrical box on generator, (refer to Figure 4).
Figure 4
Wiring diagram
NOTE- the above wire diagram represents DS-250, DS-400, DS-650 models.
75AMP 1-CONTACTOR
DS-150, DS-250
2-CONTACTOR
DS-400, DS-650