Specification Sheet

92015-250_NC 4/16
DS-X-250
Day Spa Steam Generator
Rough-In Guide
Day Spa Steam Generator
SPECIFICATIONS
Input Voltage…………….…......208-240VAC Single Phase
Kilowatt Rating……………………………………………..12.0
Maximum Amperage……………………………..….56 AMPS
Breaker Size……………………………………....….60 AMPS
Water Inlet…………………………….…...3/8” Compression
Steam Outlet………………………………….……….3/4” NPT
Drain Pan………………………………….…...…3/4” NPT
Safety Valve………………………………………..….3/4” NPT
Electrical Connection………………………………...IEC 309
Maximum Room Size (cubic Feet)………….…………...250
Number of Rooms…………………………….…..……2, 3 or 4
DS-2-250 = 2 Room, DS-3-250 = 3 Room, DS-4-250 = 4 Room
Can be plumbed up to 50 ft. from the steam room without
upsizing the generator.
Stainless steel construction throughout.
Split tank technology enhances performance and life-span.
New style Polished Chrome Steam Head.
Hardware Kit provided.
Temp Sensor is built into controller.
Optional Front Desk Sentinel Control is available & may be
located up to 100’ of cable run from the generator.
Installation Notes:
Generator must be installed by a licensed electrician.
Install this generator according to the installation guide supplied. Follow all local plumbing and electrical codes. Unit must be accessible for
service and maintenance. Generator is factory sized: L x W x H = Steam Room Cubic Feet = 250 Cu. Ft. max. Choose the appropriate generator.
For every additional foot of ceiling height over 8 ft, use the next larger generator. Always round up when calculating the total cubic feet.
Product Specification Basics:
The steam generator unit dimensions are approximately 18-3/4”L x
13-3/4”W x 16”H in dimension. The generator shall be made from
stainless steel and include: SmartSteam, PowerFlush and a Split Tank.
For any further assistance please contact ThermaSol at
800.776.0711 or sales@thermasol.com
Visit www.thermasol.com for a complete product definition
Day Spa 250 Series Standard Equipment:
Designed for Multiple steam room use, 2 to 4 Rooms.
Includes Steam Distribution System Module to deliver steam to rooms
independently. See separate Rough-in Guide.
Designed for commercial use.
Large capacity tank size.
Unit has 208-240 volt power connections to be installed by your
licensed electrician.
Superior heating elements low watt density.
Includes Stainless Steel drip pan.