(Optional) Day Spa Sentinel Installation
Instructions
1. The Day Spa Sentinel (Figure 13) can be located anywhere within 100 ft of the Steam
Distribution System (DS-SDS).
2. Install the Sentinel display 2 to 6 feet from the floor on a wall. Drill a 1-1/16” hole in the wall.
3. Bring the control cable from the Steam Distribution System (DS-SDS) through the 1-1/16”
hole. Using the coupler, connect the cable to the Sentinel connector. Ensure the coupler is
located higher in the wall than the Sentinel. Do not pinch, nail, wedge or damage the control
cable. Any damage to the control cable could result in Sentinel not working properly. If the
Sentinel is not installed immediately, protect the end connector with tape or some other kind
of shielding material.
4. Ensure the Steam Distribution System (DS-SDS) is powered-down (off). Connect the other
end of the control cable to the Steam Distribution System (DS-SDS) at the Sentinel
connection port (Figure 12).
CONNECTION PORT
(To the Sentinel display)
POWER SWITCH
Figure 12: Steam Distribution System
5. Turn on both water and power to the generator and switch on the Steam Distribution System
(DS-SDS).