Installation Sheet
81098 Page 13 of 21 REV L 10/18 NJL
STEAM HEAD INSTALLATION
Parts Enclosed
Deluxe steam head
Escutcheon
Tools Needed
Pipe wrench
7/8” cutting tool
Silicone gun
Other tools as required
IMPORTANT NOTE!
Locate the steam head 6" from any corner, 12" from the floor, and as far away as
possible from any bench, seat or door. The steam head is to be mounted as far
away as possible from typical bathing positions (seated or standing) and as far
away from the room temperature sensor as possible.
1. Drill a 7/8” diameter hole in the shower wall or wall above the bathtub for the steam outlet line.
2. Connect 1/2” copper pipe or copper tubing and 1/2” brass union onto the steam outlet. Run a 1/2”
copper pipe from the union to the 7/8” hole in wall.
3.
Attach the steam head and escutcheon to the copper pipe. CAUTION: Do not obstruct the steam
line with any shut-off valves, plugs or caps. All Steam Suite generators are designed to build
NO PRESSURE.
NOTE: Make sure the steam head ARROW is pointing UP as shown in the detail
below. Then press chrome cover over the steam head with the lettering HOT upright and readable.
4. The steam line can run up, down, or horizontal; but cannot run down and then up. If it does, a
steam trap will be produced at the low point blocking the flow of steam. Insulate the steam outlet
piping if the piping run exceeds 10 feet or is exposed to cold areas. NOTE: Use steam rated
insulation (225 °F minimum).
WARNING: Avoid contact with steam head! It will burn you. Avoid direct contact with the
steam coming out of the steam head! It is extremely hot! It will burn you!