Specification
Masonry Wall Construction - Thermasheath-3 is applied to either
the exterior or interior face of concrete or concrete masonry walls to
providealayerofcontinuousinsulation(ci)overtheentiresurface.Itmay
be secured to the inside face of a concrete or concrete masonry wall,
over or under the furring strips, and coveredwith a minimum 1/2 inch
gypsumwallboardinteriorfinish.Adhesives,screwsornailsmaybeused
to hold the Thermasheath-3 in place against the wall temporarily, until the
furring strips and gypsum wallboard are installed. The furring strips and
gypsum wallboard must be secured with suitable screws or nails.
05
Masonary Wall Construction
Thermasheath-3 Interior Application
A1.00
THERMASHEATH - 3
1/2" GYSUM WALL
BOARD
TREATED WOOD
FURRING 16" O.C.
CMU WALL
TREATED WOOD
FURRING AT BASE
TREATED WOOD
END CAP
FOUNDATION WALL
Exterior Stucco Construction - Thermasheath-3 may be
used as the insulative sheathing under hard coat stucco finishes.
It may be secured to the studs with bugle-head screws, galvanized
roofing nails or common-nails driven through cap washers. Cover the
Thermasheath-3 with a suitable separation layer such as an organic
or inorganic felt. Then, attach conventional metal wire lath and
expansion joints with appropriate fasteners as dictated by the local
Building Code. Rmax does not recommend the direct attachment of
stucco, such as Portland cement or polymer-modified types, directly
to the face of the insulation product. Consult stucco manufacturers
for details.
06
Stucco Construction
Thermasheath-3 Exterior Application
A1.00
THERMASHEATH - 3
ORGANIC / INORGANIC
FELT
METAL FLASHING
HARD COAT STUCCO
FOUNDATION WALL
SUBFLOORING &
FLOOR FRAMING
TERMITE SHIELD
VAPOR RETARDER
(if required)
METAL LATHE
FLASHING TAPE
1/2" GYPSUM
WALLBOARD
Notes:
1. Stud walls must be properly braced for lateral loads
according to the requirements of local Building Codes.
APPLICATION / INSTALLATION
Stud Wall Construction - Thermasheath-3 applied to the exterior
or interior face of studs, to cover all studs, sills, plates and header
constructions,providesalayerofcontinuousinsulation(ci)overdetails
not normally covered byinsulation products.It maybe secured tothe
framing or structural sheathing with bugle-head screws, galvanized
roofingnailsorcommonnailsdriventhroughcapwashers.Quality-grade
constructionadhesivesmayalsobeusedtosecuretheThermasheath-3
oninteriorapplications.Exteriorfacadesmayincludebrick/stoneveneer,
exterior siding and stucco. Thermasheath-3 must be covered on the
interiorwithaminimum1/2inchgypsumwallboardinteriorfinishthatis
mechanically attached.
02
Stud Wall Construction (Brick Veneer)
Thermasheath-3 Exterior Application
A1.00
THERMASHEATH - 3
AIR / WATER RESISTIVE
BARRIER (if required)
FLASHING TAPE
BRICK VENEER (Provide
weeps as required)
THRU-WALL FLASHING
(Metal)
SUBFLOORING &
FLOOR FRAMING
BRICK TIES AS REQ.
TREATED WOOD
TERMITE SHIELD
VAPOR RETARDER
(if required)
FOUNDATION WALL
1/2" GYPSUM
WALLBOARD
Notes:
1. Stud walls must be properly braced for lateral loads
according to the requirements of local Building Codes.
Cavity Wall Construction (Brick Veneer) - Thermasheath-3
is an excellent cavity insulation product fitting between the masonry
blockandfinishedbrickveneerofanyresidentialorcommercialproject.
It may be secured to the dry face of the masonry block wall with a
quality grade construction adhesive. Thermasheath-3 can be cut to fit
betweenmasonryjointreinforcementsplacedtotiethebrickveneerto
the concrete block back-up and installed horizontally in strips to allow the
walltiestoextendbeyondthefaceoftheinsulationleavingtheproper
airspacesasrequired.
04
Cavity Wall Construction (Brick Veneer)
Thermasheath-3 Exterior Application
A1.00
THERMASHEATH - 3
16" OR 24" WIDTHS AVAILABLE
TO FIT BETWEEN MASONRY
WALL TIES OR IMPALE
INSULATION OVER WALL
TIE PENTILES
BRICK VENEER (Provide
weeps as required)
THRU-WALL FLASHING
(Metal)
BRICK LEDGE
CMU WALL
FOUNDATION WALL
FLASHING TAPE
Thermasheath
®
-3