Use and Care Manual

27
Temperature
Problems What to do
Display Window
The hot water at the
xture is too hot.
Are the gas and water supply valves fully open?
[Using the optional remote controller]
Is the water temperature setting appropriate? (page 13)
[Using the optional remote controller]
If the water supply temperature is high, it is possible
for the
outlet
temperature to be higher than the
temperature set on the remote controller.
[Using the optional remote controller]
If only a low ow of hot water is demanded, it is
possible for the outlet temperature to be higher than the
temperature set on the remote controller.
The hot water at the
xture is not hot enough.
Are the gas and water supply valves fully open?
[Using the optional remote controller]
Is the water temperature setting appropriate? (page 13)
If the amount of hot water required is very high, it is
possible for the
outlet
temperature to be lower than the
temperature set on the remote controller.
Decrease the amount of hot water passing through the
unit and the temperature should stabilize.
The actual outlet water temperature is lower than the set
temperature of the unit.
Contact the nearest Noritz agent.
The water is cold when only
a single xture is open.
The unit will not heat the water if the ow rate is less
than 0.5 gallons (2L) per minute.
Open the xture more or open other xtures so that
a greater ow passes through the unit, and the unit
should begin heating again.
The unit does not re when
water is owing due to high
supply water temperature.
If you try to supply a low ow of water when the supply
water temperature is too high.
The unit will not re because it will over heat the outlet water.
Fluctuations in hot water
temperatures.
Clean the water lter of any debris. (page 22)
[Using the optional remote controller]
Setting temperature cannot rise.
Is the maximum temperature setting appropriate?
(page 14)
Amount of Hot Water
Problems What to do
Display Window
The amount of hot water
at a certain xture is not
constant.
When hot water is demanded at other xtures, the
amount available may be reduced. The maximum
ow available from this unit is 5.3 GPM (20L/min.) at a
45°F (25°C) temperature rise.
Pressure uctuations and other plumbing conditions
can cause the temperature and pressure at a xture to
be unstable, but it should stabilize after a short time.
There are some types of hot water taps that discharges
large volumes of hot water at rst but stabilize after time.
To keep the temperature stable, the heater limits the
amount of water that can ow through it to a low ow
initially, but the amount increases over time.
[Using the optional remote controller]
The amount of hot water in
the tub is less/more than the
set amount when using the
ow meter alarm feature.
When hot water is used for other xtures while lling
the bath tub, the tub will not ll as much.
If there is water in the tub already, or when lling is
stopped and restarted, the tub will ll more.
[Using the optional remote controller]
The ow meter alarm does
not sound even when lled
to the set amount.
The ow meter alarm is set to sound when hot water is
continuously discharged for the set volume of water.
If mixing valves are used, or if cold water is mixed
with hot water at the xture, the tub will ll more than
the setting of the ow meter alarm.
Amount of hot water
available has decreased
over time.
Is the water lter clogged? (page 22)
If the supply water is hard and has not been treated,
scale can build-up in the water heater and decrease
the maximum amount of hot water available. Scale can
be removed from the water heater by ushing the unit
periodically. To prevent scale from forming in the water
heater, a water softener or scale inhibitor is recommended.
Optional Remote Controller
Problems What to do
Display Window
The light on the power
button does not come on.
Has there been a power failure?
Is the power connected properly?
The water temperature changes
after a power failure or when
the power is disconnected.
The temperature setting and the ow meter alarm
setting may both need to be reset after a power
outage.
The plastic on the surface
or buttons of the remote
controller has torn,
peeled, or air bubbles
inside.
The surface of the remote controller is afxed with a
protective sheet (to prevent surface scratching, etc.) at
time of shipment. This sheet can be removed or left as it
is. When leaving the protective sheet on, areas frequently
touched may tear or peel. However, the remote controller
will not malfunction from water entering such torn or
peeled areas. To restore the appearance of the remote
controller surface, simply remove the protective sheet.