iMON & iMEDIAN Installation Guide Revised on November 11, 2005 SoundGraph, Inc.
Table of Contents In your Package 3 1. iMON 2.4G LT 3 2. iMON 2.4G DT 3 3. iMON Station 4 4. iMON Knob 4 5. iMON Inside 4 6. iMON VFD 4 7. iMON OEM 5 S/W, H/W Installation 6 1. S/W Installation 6 2. H/W (IR Receiver) Installation 6 1) External RF Receiver (iMON 2.4G LT) Installation 6 2) Internal RF Receiver (iMON 2.
In your Package SoundGraph, Inc. has six different iMON models which have different types of Remote Controller and Receiver. Please check the components in your box according to the following picture. 1. iMON 2.4G LT In the Box : 1 iMON 2.4G Remote Controller, 1 iMON 2.4G LT Receiver (External RF Receiver), 1 Installation CD (iMON Manager, iMEDIAN), 1 Quick Guide, 2 AAA Batteries 2. iMON 2.4G DT In the Box : 1 iMON 2.4G Remote Controller, 1 iMON 2.
In the Box : 1 iMON PAD Remote Controller, 1 iMON Station (External IR Receiver), 1 Extension USB Cable, 1 Installation CD (iMON Manager, iMEDIAN), 1 Quick Guide, 2 AAA Batteries 4. iMON Knob In the Box : 1 iMON PAD Remote Controller, 1 iMON Knob (External IR Receiver), 1 Extension USB Cable, 1 Installation CD (iMON Manager, iMEDIAN), 1 Quick Guide, 2 AAA Batteries 5.
In the Box : 1 iMON PAD Remote Controller, 1 iMON VFD (Internal IR Receiver), 1 Extension USB Cable, 1 Installation CD (iMON Manager, iMEDIAN), 1 Quick Guide, 2 AAA Batteries 7. iMON OEM SoundGraph provides iMON OEM version to different OEM partners who use iMON/iMEDIAN for their products. iMON OEM version has a different packages according to the request of our OEM partners. Please check the Remote Controller, IR Receiver and Installation CD in your package.
S/W, H/W Installation Please read the Quick Guide and this Installation Guide carefully before your installation of iMON IR Receiver. 1. S/W Installation Please install the S/W first before you connect the H/W to your PC. Insert ‘iMON, iMEDIAN Installation CD’ to your CD ROM, and install the S/W application to the PC according to the following installation process. There are two different applications on the installation CD.
Step 1. Plug ‘iMON 2.4G DT receiver’ to the PCI slot of mainboard. Disconnect ‘PC Case Power Button Cable’ from the ‘Power Switch’ connector on the main board and Connect ‘PC Case Power Button Cable’ to ‘CN3 connector’ on the iMON 2.4G DT receiver.
Step 3. Connect ‘Mainboard Power Switch Cable’ to the ‘Power Switch’ Connector on the mainboard from ‘CN2 connector’ on the iMON 2.4G DT receiver. Step 4. Connect ‘Internal or External USB cable’ to the ‘mainboard internal USB connector’ or ‘external USB connector’ and ‘CN4 connector’ on the iMON 2.4G DT receiver. CN1 connector is reserved for the future use. You don’t need to connect any cable to this CN1 connector. iMON 2.
BALCK GND, GROUND USB Port Pin Name 3) External IR Receiver (iMON Station, iMON Knob) Installation Connect your External iMON IR Receiver (iMON Station or iMON Knob) to your USB port. If you connect the iMON IR Receiver before the S/W installation, then assign the H/W driver according to the ‘Found New H/W Wizard’. Select CD ROM drive for searching H/W driver which has the installation CD inside.
Internal IR Receiver (iMON Inside, iMON VFD) Connection Diagram A1 : (3pin, iMON Inside/VFD ‘ST PWR1’ Connector) A2 : (3pin, Mainboard Power Extension Cable) ① Stand-By Power Connection Cable B1 : (2pin, iMON Inside/VFD ‘M/B PWR’ Connector) B2 : (2pin, Mainboard Power Switch Connector) ② Mainboard Power Switch Connection Cable C1 : (2pin, iMON Inside/VFD ‘PWR S/W’ Connector) C2 : (2pin, PC Case Power Button) ③ PC Case Power Switch Connection Cable D1 : (5pin, iMON Inside/VFD USB Connector) D2 : (4pi
Line Color Additional USB Port Pin Name RED VCC, POWER, USBPOWER WHITE D-, DATA-, USBP#-, UP#-, P#- GREEN D+, DATA+, USBP#+, UP#+, P#+ BALCK GND, GROUND USB Port Pin Name -11-
FCC Certification This device complies with Part15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operations. INFORMATION TO THE USER This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
CE Certification Declaration of Conformity I hereby declare that the product USB RF Remote Controller, iMON 2.4G, iMON 2.4GLT/DT satisfies all the technical regulations applicable to the product within the scope of Council Directives 73/23/EEC, 89/336/EEC and 99/5/EC: EN 60 950 EN 301 489-1V1.3.1, EN 301 489-3 V.1.4.1 EN 300 440-1 V1.3.1 EN 50 371 All essential radio test suites have been carried out. MANUFACTURER or AUTHORISED REPRESENTATIVE: − Address: SoundGraph Inc.
About S/W Updates iMON and iMEDIAN will be continuously updated through the SoundGraph website (http://www.soundgraph.com). If you have any difficulties to use iMON, iMEDIAN and iCASTER or have any question about our product, please send an email to iMON@soundgraph.com or post the message on our website.
About SoundGraph, Inc. ● Address 621-1 YeokSam 1-Dong, GangNam-Gu, Seoul, Korea 135-908 ● Telephone +82-2-569-2097 ● Fax +82-2-569-2090 ● Web Site http://www.soundgraph.com ● E-Mail iMON Development Team : iMON@soundgraph.com iMON Sales Team : sales@soundgraph.com 1. It is strictly prohibited to copy or publish this user’s manual online without consent of SoundGraph Co., Ltd. 2.