Working principle
Channels are formed between the plates and the corner ports
are arranged so that the two media ow through alternate
channels. The heat is transferred through the plate between
the channels, and complete counter-current ow is created
for highest possible efciency. The corrugation of the plates
provides the passage between the plates, supports each
plate against the adjacent one and enhances the turbulence,
resulting in efcient heat transfer.
Standard materials
Frame plate
Mild steel, Epoxy painted
Nozzles
Carbon steel
Metal lined; Stainless steel, Titanium
Plates
Stainless steel AISI 316 or Titanium
Gaskets
Field gaskets Nitrile, EPDM
Ring gaskets Chloroprene, EPDM
Connections
FG PED Size 100 mm DIN PN16
FG ASME Size 4" ANSI 150
FD PED Size 100 mm DIN PN25
FD ASME Size 4" ANSI 300
REF PED Size 100 mm Pipe
Technical data
Mechanical design pressure (g) / temperature
FG PED 1.6 MPa / 180°C
FG ASME 150 psig / 350°F
FD PED 2.5 MPa / -50 to 180°C
FD ASME 300 psig / -40 to 350°F
REF PED 2.5 MPa / -50 to 150°C
Maximum heat transfer surface
75 m² (825 sq. ft)
Flow principle of a plate heat exchanger
All rights reserved for changes in specications



Dimensions
Measurements (mm)
Type H W h
M10-FG 1084 470 215
M10-FD 981 470 131
M10-FD ASME 1084 470 215
M10-BW REF 1110 470 163
The number of tightening bolts may vary depending on pressure rating.
Particulars required for quotation
– Flow rates or heat load
– Temperature program
– Physical properties of liquids in question (if not water)
– Desired working pressure
– Maximum permitted pressure drop
– Available steam pressure