User Manual

www.thermaltransfer.com TTPSales@thermasys.com 262.554.8330
77
WATER COOLED EK
Performance Curves
1:1 Oil to Water Ratio – High Water Usage
Weights (lbs)
Models Net Approx. Shipping
1. EK-505-0 6 7
2. EK-508-0 7 8
3. EK-510-0 8 9
4. EK-512-0 9 10
5. EK-514-0 10 11
6. EK-518-0 11 12
7. EK-524-0 13 14
8. EK-536-0 17 18
9. EK-708-0 15 16
10. EK-712-0 18 19
11. EK-714-0 19 20
12. EK-718-0 22 23
13. EK-724-0 26 28
14. EK-736-0 34 36
15. EK-1012-0 35 37
16. EK-1014-0 38 40
17. EK-1018-0 42 45
18. EK-1024-0 50 55
19. EK-1036-9-0 67 85
20. EK-1036-6-0 67 85
21. EK-1048-8-0 78 95
22. EK-1048-6-0 78 95
8
9
10
15
20
25
30
40
50
60
70
80
90
100
150
200
250
300
400
500
7
6
5
3
2
4
2.5
2 9 10 15 20 25 30 40 50 608765432.5
OIL FLOW (GPM)
HORSEPOWER REMOVED IN COOLER
1
2
3
5
4
6
9
12
10
13
15
16
17
18
19
20
21
22
14
11
7
8
OIL P
= 5 PSI
= 10 PSI
= 20 PSI
9 10 15 20 25 30 40 50 60
8
9
10
15
20
25
30
40
50
22
21
20
19
18
17
14
13
12
10
9
7
8
6
5
3
1
2
4
11
16
15
60
70
80
90
100
150
200
250
7
6
5
3
2
4
2.5
8765432 2.5
OIL FLOW (GPM)
HORSEPOWER REMOVED IN COOLER
OIL P
= 5 PSI
= 10 PSI
= 20 PSI
Weights (lbs)
Models Net Approx. Shipping
1. EK-505-T 6 7
2. EK-508-T 7 8
3. EK-510-T 8 9
4. EK-512-T 9 10
5. EK-514-T 10 11
6. EK-518-T 11 12
7. EK-524-T 13 14
8. EK-536-T 17 18
9. EK-708-T 15 16
10. EK-712-T 18 19
11. EK-714-T 19 20
12. EK-718-T 22 23
13. EK-724-T 26 28
14. EK-736-T 34 36
15. EK-1012-T 35 37
16. EK-1014-T 38 40
17. EK-1018-T 42 45
18. EK-1024-T 50 55
19. EK-1036-9-T 67 85
20. EK-1036-6-T 67 85
21. EK-1048-8-T 78 95
22. EK-1048-6-T 78 95
2:1 Oil to Water Ratio – Medium Water Usage