Manual
AHP
www.thermaltransfer.com TTPSales@thermasys.com 262.554.8330
145
AIR COOLED AHP
Dimensions
AHP Series with AIR MOTOR
Approx.
D H J Shipping
Model A B C Approx. E F G NPT NPT PSI
(1)
CFM
(2)
Wt. (lbs.)
AHP-400 22.68 17.96
13.55
13.96 18.68
2.00 .25
60 50 105
AHP-725 34.20 30.56 22.37 18.37 26.56 85 45 140
AHP-950 37.24
26.78
19.01
22.78
33.24
.50
60 55 425
AHP-1200
41.19
20.50
37.19
3.00 70 100 481
AHP-1600 34.89 17.06 30.00 30.89 1.00 100 180 595
AHP-2000
36.01
51.04 37.88
22.23
33.88 47.04
90 230
700
AHP-2500 49.07 43.70 39.70 45.07 4.00 1.25 735
AHP-3000
51.04
52.52
23.56
48.52
47.07
100 275
795
AHP-3500 56.30 52.30 825
Note: We reserve the right to make reasonable design changes without notice. All dimensions are in inches.
(1)
Air inlet to the air motor must be regulated to this pressure.
(2)
CFM (Free Air) consumption of the air motor. Lubrication = One drop of oil for every 50-75 CFM of air going through the motor.
Use detergent SAE #10 oil. Filter, regulator and lubricators for the air motors are required, but not included.
AIR