Contactor Replacement
6. RemovethecontactorfromthemetalbaseoftheCutmaster.
CAUTION
NOTEALLWIRELOCATIONS.DONOTMISWIREUNITASNON-REPAIRABLEDAMAGEWILL
OCCURTOTHECONTACTORANDPCB.
NOTE
Notationsinfollowingillustrationdesignatepermanentwireconnectionstothe9X160contactor.Addi-
tional connections are noted for single and three phase on the labels internal to the True Series CutMaster
andnexttothecontactor(ifapplicable).
7. ReconnectACpowercordasprevious.USET-20TorxScrewdriveroncontactorconnectionlugs,useneedle
nosedpliersonspadeconnections.CM12,20,25&40UNITSWITHCEFILTERS:Removewires#5&#6from
the contactor and replace with the harness included with the enclosure kit. This will involve clipping wire ties
asinFigure16.RemoveJ6fromtheMainPCBandreplacewiththeharnessconnection.
Figure8:LoadSideConnectionsFigure9:LineSideConnections
NOTE
Anadditional#10AWGblackwirejumpermaybeconnectingL1toL4,re-installthis,ifpresentandbend
wiretottheenclosure.SeeFigure20.