Product Manual

Manual 0-5185
11
APPENDIX: RAW ARC VOLTAGE
Ifrawarcvoltageisnecessaryforthetorchheightcontrol,thecustomermustsupplyan18AWG(1.0mm
2
),single
pair,unshieldedcableratedfor300Vorgreater.Allworkmustbeperformedfollowingapplicablelocalandnational
codes.
1. Disconnectthepowerfromthepowersupply.
2. Removethescrewsthatattachthepowersupplycovertothechassis.Removethecover.
3. Routethecablethroughthecustomersuppliedstrainreliefattherearofthepowersupply.
Art # A-10286
Cut out for cable
4. Onthemainboarduseinsulatedtype1/4-inchringlugterminalendstoconnectto–Vout1(-polarity)andWORK
1(+polarity).
!
WARNING
Therawarcvoltagecanexceed350VDC!!!!
-V OUT 1
WORK 1
J10
-V OUT 1
WORK 1
Art # A-10287