ELECTRICAL REQUIREMENTS & GROUNDING INSTRUCTIONS
THIS APPLIANCE MUST BE CONNECTED TO
RECEPTACLE ON A CIRCUIT RATED 120
VOLTS, 15 AMPERE, 60 Hzo
Always disconnect electric supply cord from wall
outlet before servicing this appliance.
Observe all governing codes and ordinances when
grounding. In the absence of these codes or ordi-
nances observe National Electrical Code ANSI/
NFPA No. 70 Current Issue.
This appliance is factory equipped with a power
supply cord with a three-prong grounding plug.
IT MUST BE PLUGGED INTO A MATING
GROUNDING TYPE RECEPTACLE, CON-
NECTED TO A CORRECTLY GROUNDED 120
VOLT CIRCUIT. If the circuit does not have a
grounding type receptacle, it is the responsibility
and obligation of the installer or user to have the
existing receptacle changed to a properly grounded
and polarized receptacle in accordance with all
applicable local codes and ordinances by a quali-
fied electrician. In the absence of local codes and
ordinances, the receptacle replacement shall be in
accordance with the National Electrical Code. THE
THIRD GROUND PRONG SHOULD NOT,
UNDER ANY CIRCUMSTANCES, BE CUT OR
REMOVED. See Fig. Ao
if there is any doubt as to whether the wall recep-
tacle is properly grounded, the customer should
have it checked by a qualified electrician.
Cold water pipe must have metal continuity to the
electrical ground and not be interrupted by plastic,
rubber or other electrically insulating connectors
(including water meter or pump) without adding
a jumper wire at these connections. See Fig. B.
FIGURE A
Receptacle Box Three-Prong
Cover Plate Fteceptacie
FIGURE B
No. 4 wire