Installation Guide
Page 19
Install electrical wiring
CAUTION: Installation work and electrical wiring must be done
by qualied person(s) in accordance with all applicable codes,
regulations, and standards, including re-rated construction.
CAUTION: Do not use an extension cord. If the product power
cord is too short, have a qualied electrician install a three slot
receptacle.
1. Install a standard wiring box, with 3-pronged receptacle, within reach
of the downdraft’s power cord.
2. Remove electrical panel wiring box cover. Secure blower power cable
to electrical panel wiring box with U.L. approved strain relief.
Based on blower selected, go to the relevent
section:
A - Flex Blower Wiring
B - Remote Blower Wiring
A - Flex Blower Wiring
3. Connect exible blower wires to wires in electrical panel wiring box
as shown. Cap off BLUE wires (LOW 1).
4. Replace wiring box cover.
B - Remote Blower Wiring
REMOTE
BLOWER
M
ELECTRICAL PANEL
WIRING
BOX
BLACK (HIGH 4)
WHITE (NEUTRAL)
BLUE (LOW 1, CAP OFF)
GRAY (MED 2)
GROUND SCREW
ORANGE (MED-HIGH 3)
14/4 ROMEX
OR CONDUIT
Note: Some blowers may come with plugs or connectors, these
should be removed and the 14/4 ROMEX or Conduit wiring should be
connected in an approved junction box.
5. Connect power wires to wires in electrical panel wiring box as shown.
Cap off Low (Speed 1) wires.
6. Replace wiring box cover.
Connect downdraft to power
LOWER
RECEPTACLE
ELECTRICAL
PANEL CABLE
CABINET BOTTOM
1.
Plug electrical panel cable into lower receptacle as shown.
Plug the downdraft’s power cord into the 3-pronged receptacle.
Make sure that the power cord is routed away from the heat
generated by the cooktop.
2.
Check operation.
3. Remove all protective lm and packaging before operation. In order to
remove all protective lm and packaging, raise the intake housing and
remove the front panel to access the lter area.
INSTALLATION
CAUTION: Installation work and electrical wiring must be done
by qualied person(s) in accordance with all applicable codes,
regulations, and standards, including re-rated construction.
3. The following exterior or inline blowers can be used:
VTR630P - 600 cfm (17 m
3
/min) Remote Blower
VTI610P - 600 cfm (17 m
3
/min) Inline Blower
120 VAC • 60 Hz • 5.0 A (max.)
4. Install a standard wiring box, with 3-pronged receptacle, within reach
of the downdraft’s power cord.
CAUTION: Installation work and electrical wiring must be done
by qualied person(s) in accordance with all applicable codes and
standards, including re-rated construction.
WIRING BOX
COVER
FLEXIBLE
BLOWER
M
ELECTRICAL PANEL
WIRING
BOX
BLACK (HIGH 4)
WHITE (NEUTRAL)
GRAY (MED 2)
GROUND SCREW
ORANGE (MED-HIGH 3)
BLACK
WHITE
BLUE (CAP OFF)
RED
ORANGE
GREEN