Installation Guide
Page 15
A - Installation using flexible blower
attached to downdraft
FRONT
PANEL
FLEX
BLOWER
If blower
discharge is
down,
electrical
panel must be
relocated.
(Purchase Model VTD600P Flexible Blower separately.)
1. Remove hex nuts to remove front panel cover.
2. Determine whether ex blower will discharge to the left, right,
ordown.
3. If blower discharge is down, remove (4) #8-32 hex nuts and
electricalpanel.
4. Place blower over studs around front panel opening.
5. Tighten hex nuts to secure blower in place.
Based on blower and ducting option selected,
go to the relevent section:
A - Installation using flexible blower
attached to downdraft
B - Installation using flexible or remote
blower - mounted in a remote location -
ducting through front panel opening
C - Installation using flexible or remote
blower - mounted in a remote location -
ducting through left, right or rear
BLOWER
SUPPORT LEGS
(4) BOLTS
5. Remove bolts from ex blower housing. Attach blower support legs
to ex blower housing with these (4) bolts. Do not tighten bolts at
this time.
B - Installation using inline or remote
blowers - with ducting through front
panel opening
CAUTION
If exible blower is mounted as an inline blower: Do not use legs
alone for support. It may be necessary to add extra support for
the exible blower.
FRONT
PANEL
6", 8", OR 10” (152MM, 203MM,
OR 254MM) ROUND
REMOTE ROUGH-IN
PLATE (Purchase Separately)
If blower
discharge is
down,
electrical
panel must be
relocated.
1. Remove hex nuts to remove front panel cover.
2. If blower discharge is down, remove (4) #8-32 hex nuts and
electricalpanel.
3. Place 6”, 8”, or 10” (152mm, 203mm, or 254mm) round rough-in
plate (purchase separately) over studs around front panel opening.
4.
Tighten hex nuts to secure remote discharge plate in place.
INSTALLATION