design guide electric cooktops

1.800.735.4328 | THERMADOR.COM
129
36-INCH ELECTRIC COOKTOP AND CUTOUT DIMENSIONS
INSTALLATION OPTIONS
INSTALLATION ABOVE A WALL OVEN OR
WARMING DRAWER
Thermador Masterpiece® Electric Cooktops may be
installed above a Thermador Single Built-in Oven as
long as there is no contact between the bottom of the
cooktop and the top of the oven.
Thermador Masterpiece Electric Cooktops may also
be installed above a Thermador Warming Drawer
to create a convenient cooking center. Refer to the
warming drawer section for additional specifications.
IMPORTANT
We strongly recommend the installation of a
Thermador Ventilation System with all Masterpiece
Electric Cooktops.
Seal the surfaces of the cutout to make them heat
resistant. This prevents the surfaces from expanding as
a result of humidity.
Solid surface countertops require a special cutout and
installation. For example, heat reflective tape or
rounded corners may be necessary. Contact the
countertop manufacturer for instructions specific to
your countertop.
WARNING
To reduce the risk of ignition of nearby combustible
materials, install the countertop with a minimum
distance of 2" (51mm) from both side walls and the
back wall.
COOKTOPS 36-INCH ELECTRIC
Models: CEM365FS, CET366FS
COOKTOPS — ELECTRIC
COUNTERTOP REQUIREMENTS
INSTALLATION ABOVE A THERMADOR
BUILT-IN OVEN
27
1
/16"
(687mm)
29
1
/16"
(738mm)
24
7
/16"
(621mm)
36"
(914mm)
SUMP
4
3
/16"
(106mm)
3
15
/16"
(100mm)
4
15
/16"
(125mm)
6
3
/4"
(172mm)
1
13
/16"
(47mm)
1
/4"
(7mm)
4
3
/4"
(121mm)
Note: Dimensions based on standard countertop height (36" with 4
3
/4
" toe kick
including base plate).
The built-in oven can be installed below the electric cooktop as long as ther
e is
no contact between the bottom of the cooktop and the top of the oven.
TOE KICK
COOKTOP
OVEN
TOE KICK
COUNTERTOP
3"(76mm)
28
1
/4"
(718mm)
Fitting/
Conduit