Installer checklist
Final check
Gas supply
Electrical
Operation
Clean and protect exterior surfaces 
• Always wipe in the direction of the stainless steel 
grain.
• To condition and protect stainless steel, use the 
Thermador Stainless Steel Conditioner, which can be 
purchased in the Thermador eShop (thermador.com/
customer-care).
• DO NOT allow deposits to remain for long periods of 
time.
• DO NOT use ordinary steel wool or steel brushes. 
Small bits of steel may adhere to the surface causing 
rust.
• DO NOT allow salt solutions, disinfectants, bleaches 
or cleaning compounds to remain in contact with 
stainless steel for extended periods. Many of these 
compounds contain chemicals which could prove 
harmful. Rinse with water after exposure and wipe dry 
with a clean cloth.
• Refer to the Use and Care Guide for additional 
information.
Troubleshooting
See Use and Care Guide for troubleshooting information.
Specified clearances maintained to cabinet 
surfaces.
Unit level – front to back – side to side.
Burner caps positioned properly on burner bases.
All packaging material removed.
Kick panel in place and screws secure.
Verify flame at each burner. Flame may need to 
burn for several minutes to remove impurities from 
the gas lines.
Verify that the ExtraLow
®
 feature works and relights 
around the entire burner.
INSTALLER: Leave the Home Connect™ instruction 
leaflet with the owner of the appliance. In order to 
utilize the full feature potential of the appliance, the 
owner should download the Home Connect™ app 
on their smart device and pair the appliance to the 
home's Wi-Fi device. 
Gas Connection: ¾'' (19 mm) N.P.T. with a min. ¾'' 
(19 mm) diameter flex line. 
The appliance is connected only to the type of gas 
for which it is certified for use.
Manual gas shut off valve installed in an accessible 
location (without requiring removal of range). 
Owner is aware of location of the gas shut-off valve.
Unit tested and free of gas leaks.
If used on propane gas, verify that the propane gas 
supply is equipped with its own high pressure 
regulator in addition to the pressure regulator 
supplied with the appliance.
Gas supply pressure does not exceed 14'' W.C. 
(34.9 mb). 
Receptacle with correct over-current protection is 
provided for service cord connection.
Proper ground connection.
Owner is aware of location of the main circuit 
breaker.
Bezels centered on burner knobs, and knobs turn 
freely.
Each burner lights satisfactorily, both individually 
and with other burners operating.
Oven door hinges seated and hinge locks in proper 
position. Oven handle and door is level and 
centered. Door opens and closes properly.
Burner grates correctly positioned, level, and do not 
rock.
INSTALLER: Write the model number and serial 
number in the Use and Care Guide. Leave the Use 
and Care Guide and Installation Manual with the 