Installation Guide
Table Of Contents
Page. 21
3-wire lead connection
Where local codes and ordinances permit grounding 
through neutral, and conversion of supply to 4-wire is 
impractical, the unit may be connected to the power 
supply with a Listed (UL, CSA, ...) 3-POLE, 3-
CONDUCTOR cord kit rated 125/250 VOLTS, 50 
AMPERES DEDICATED CIRCUIT, and marked for use with 
ranges. It is the responsibility of the installer to provide 
the proper wiring components (cord, wires, etc.) and 
complete the electrical connection as dictated by local 
codes and ordinances, and/or the National Electrical 
Code.
The cord kit must be attached to the range back panel 
with a strain relief which will fit a 1" (25.4 mm) diameter 
hole. If not already equipped, the cord must also have 
1/4'' (6 mm) faston closed-loop lugs attached to the free 
ends of the individual conductors, preferably soldered in 
place.
To wire a 3-wire connection
1. Locate the small bag with white jumper wire located in 
the literature packet. 
2. Locate the terminal block on the rear of the unit and 
remove cover.
3. Remove upper nuts only from the terminal block 
studs. DO NOT remove nuts which secure range 
internal wiring leads.
4. If applicable, remove the 4-wire power cord from the 
appliance.
5. Mount strain relief (not provided with range) into the 
1'' (25.4 mm) diameter hole in the back panel located 
below the terminal block. Route wires up through 
strain relief.
6. Secure the neutral, grounded wire of the supply 
circuit, to the center stud (silver colored) of the 
terminal block.
7. Secure the L1 (red) and L2 (black) power leads to the 
outside corresponding terminal block studs (brass 
colored).
8. Remove the green ground screw and serrated washer 
located beneath the terminal block. Screw one end of 
the included white jumper wire to the chassis beneath 
the terminal block with the green ground screw. 
Secure the other end of the wire to the center stud of 
the terminal block with nut.
9. Tighten nuts securely. 
10. Reinstall the terminal block cover.
a – Red/L1 b – Ground link wire provided 
in small bag.
c – White/neutral d – Black/L2
d
c
a
b