Installation instructions
Table Of Contents
- Table of
- Safety
- Safety
- READ AND SAVE THESE INSTRUCTIONS
- Before you begin
- General information
- Installation considerations
- Electrical requirements
- Ductwork preparation
- Choosing the correct blower
- Attaching the hood transition
- Wall mount installation
- Discharge direction
- Cabinet installation
- Blower motor installation
- Electrical wire connection
- EXTNCB25W 25 ft. remote and in-line blower extension cable (optional)
- Built-in remote control accessory (optional)
- Make-up air damper relay switch (optional)
- Duct cover installation (optional)
- Installing grease trays, filters and spacers
- Heat lamp installation
- Installer checklist
- Before calling service
- Product data rating label
- Avant de commencer
- Renseignements généraux
- Facteurs à prendre en compte pour l'installation
- Exigences électriques
- Préparation du conduit d’aération
- Configurations de conduits courants
- Choix d'un ventilateur adéquat
- Assemblage du raccord
- Installation murale
- Installation sous une armoire
- Installation du ventilateur
- Branchement des câbles
- Câble de connexion du ventilateur EXTNCB25W (optionnel)
- Commutateur à relais pour clapet d'appoint d'air (facultatif)
- Installation de la commande à distance (optionnel)
- Assemblage du recouvrement de conduit (optionnel)
- Commutateur à relais pour clapet d'appoint d'air (facultatif)
- Installation des filtres, des plateaux à graisse et des pièces d’espacement
- Remplacement des lampes infrarouges
- Liste de vérification à l’intention de l’installateur
- Avant d’appeler le service à la clientèle
- Plaque signalétique du produit
- Antes de comenzar
- Información general
- Factores a tener en cuenta para la instalación
- Exigencias eléctricas
- Preparación del conducto de aireación
- Configuraciones de conductos comunes
- Elección de un ventilador adecuado
- Junta de la campana
- Instalación mural
- Preparación de la pared trasera
- Instalación bajo un armario
- Instalación del motor del ventilador
- Conexión de los cables
- Cable de conexión del ventilador EXTNCB25W (opcional)
- Interruptor de relé de regulador de tiro de aire de compensación (opcional)
- Instalación del mando a distancia (opcional)
- Instalación de la cubierta para el conducto (opcional)
- Instalar filtros, bandejas para la grasa y separadores
- Reemplazo de las lámparas infrarrojas
- Lista de chequeo para el instalador
- Antes de solicitar servicio
- Placa de señalización del producto
- Blank Page
- Blank Page
- Blank Page
- Blank Page
4
Advanced planning
Before you begin
9 WARNING
Improper installation of gas appliances and ventilation
hoods can create a risk for carbon monoxide which can be
harmful. To reduce the risk of carbon monoxide poisoning,
ensure the gas appliance is properly installed according to
the manufacturer’s instructions, as well as ensuring the
hood is vented to the outside for proper exhausting of
gases or fumes.
Gas cooking appliances release carbon monoxide that can
be harmful or fatal if inhaled. To reduce the risk of fire and
to properly exhaust air, the exhaust gases extracted by the
hood should be vented outside of the building only.
Consult local building codes for requirements or
restrictions related to installation of ventilation products in
recirculation mode.
Hood installation height above a cooktop, rangetop or
range can vary. To obtain the necessary installation height
above a cooktop, rangetop or range, consult the
appliance's installation manual or combination matrix.
NOTICE: The hood can be damaged from excessive heat
if a range or rangetop is operated with multiple burners at
high settings under a hood that is installed at minimum
clearances and is turned off.
Distance from cooking surface
The installation height above a cooktop, rangetop or
range is recommended as a minimum height of 30''
(762 mm); however, it is necessary to follow the cooking
appliance manufacturer's installation instructions for
proper hood height.
Refer to local building codes for the latest requirements or
restrictions when installing ventilation products in
recirculation mode.
Parts included
• Metal transition with backdraft damper
• Stainless steel baffle filters
• Stainless steel grease trays
• Stainless steel filter spacers
• Heat lamps (on PHxxGWS models)
• Blower adapter
• Wood support bracket used as hood mounting
bracket (part of install- DO NOT THROW AWAY)
• Fastener assortment*
* Hardware provided is for mounting through standard
thickness drywall or plaster into wood studs. Installers are
responsible to provide hardware for other types of
mounting situations.
Tools and parts needed
• Blower (refer to the Ventilation Planning Guide for
compatible blowers)
• Ducting as needed (refer to the “Equivalent duct
lengths for commonly used transitions” table)
• Aluminum tape (DO NOT use duct tape.)
• 1/2'' (13 mm) conduit if required (follow local codes)
• 1'' (25.4 mm) strain relief
• Cross-head screwdriver
• T-20 star-head screwdriver
• Drill with 3/16'' (4.76 mm) drill bit
• 11/32'' nut driver or socket and ratchet
• Circular saw or jigsaw
• Tape measure
• Protective work gloves
IMPORTANT: DO NOT throw away any packaging until
appliance is fully installed.
Optional accessories available for separate purchase
Refer to www.thermador.com for more details.
Accessories Description
EXTNCB25W 25 ft. remote and in-line blower
extension cable
EXTNSET4 25 ft. remote and in-line blower
extension cable adapter kit
RFPLT600P Roof plate for use with remote
blower VTR1FZ
RFPLT1000P For use with remote blower VTR2FZ
REMCPW Remote control panel