Installation instructions

Table Of Contents
12
9. On the wood bracket, mark the locations used to
hang the hood according to the table below.
10. Drill a 3/16'' (4.8 mm) tap hole through the wood
support bracket and wall. These 5/8'' (16 mm) screws
do not need to go into the studs.
11. Use (2) 5/8'' (16 mm) screws to secure the wood
bracket leaving ¼'' (6 mm) of each screw exposed for
hanging the hood.
Discharge direction
Vertical discharge cutout
Vertical discharge installations require a cutout in the
ceiling to accommodate 10'' (254 mm) duct and 5/8''
(16 mm) diameter clearance hole for ½'' (12.7 mm)
conduit to the junction box.
Horizontal discharge cutout
Horizontal discharge requires a wall cutout to provide
clearance for the transition. The location of the cutout is
determined by the hood installation height.
Prepare for the wire routing
12. Remove junction box channel covering the wires
(figure, A).
13. Remove one circular knockout behind junction box
channel (figure, B).
Hood size A
30'' (762 mm) 13'' (330 mm)
36'' (914 mm) 16'' (406 mm)
42'' (1,067 mm) 19'' (483 mm)
48'' (1,219 mm) 22'' (559 mm)
54'' (1,372 mm) 25'' (635 mm)
60'' (1,524 mm) 28'' (711 mm)
Hood size A
30'' (762 mm) 15'' (381 mm)
2 x 1½" (38) 2" (51)
A
A
A
A
inches (mm)
A
A
A
6
" (152)
6
" (152)
6
" (152)
Conduit
Zone
Conduit
Zone
Conduit
Zone
12
" (305)
12
" (305)
12
" (305)
inches (mm)
36'' (914 mm) 18'' (457 mm)
42'' (1,067 mm) 21'' (533 mm)
48'' (1,219 mm) 24'' (610 mm)
54'' (1,372 mm) 27'' (686 mm)
60'' (1,524 mm) 30'' (762 mm)
Hood size A
30'' (762 mm) 15'' (381 mm)
36'' (914 mm) 18'' (457 mm)
42'' (1,067 mm) 21'' (533 mm)
48'' (1,219 mm) 24'' (610 mm)
54'' (1,372 mm) 27'' (686 mm)
60'' (1,524 mm) 30'' (762 mm)
Back Wall
12" (305)
5¼" (134)
5¼" (134)
5¼" (134)
Hood mounting heights
30"– 40" (762 –1016) from cooking surface.
Hood mounting heights
30"– 40" (762 –1016) from cooking surface.
Hood mounting heights
30"– 40" (762 –1016) from cooking surface.
Electric
Conduit
Zone
A
A
12
"
(305)
12
"
(305)
12
"
(305)
inches (mm)
A
B