Installation Guide
Page. 17
2. Connect black wire to power supply black wire, white
wire to power supply white wire and green wire to
green wire or bare wire.
3. Place all wiring connections inside the junction box
channel. Reinstall on the top plate. Ensure that the
wires are secure and that no wires are pinched.
EXTNCB25W 25 ft. remote and in-line
blower extension cable (optional)
To connect the extension cable to the hood
1. Route the hood’s internal blower harness through the
strain relief.
2. Connect the 25 ft. extension cable to the blower
harness outside the hood.
NOTE: Cutting of the connector will void the warranty of
the appliance.
The blower extension cable is compatible with the
following in-line and remote blowers:
Make-up air damper relay
switch (optional)
Local codes may require the use of an additional backdraft
and/or make-up air damper. Contact your local HVAC
professional for specific requirements.
This hood provides a relay switch to connect a make-up air
damper (120V max). Installations will vary according to the
location in the home where the unit is installed and the
damper used. Use the following illustration as guidance
for your installation. Always comply with local code
requirements.
To connect the make-up air damper relay switch
1. Access the hood’s wiring.
2. Route the make-up air damper harness through the
strain relief to the terminal block.
• The make-up air kit hot and return connections
can use either terminal connection. There is no
polarity requirement for the two pin terminal
block.
3. Secure the ground wire with the green T-20 ground
screw.
1 Connects to the hood
2 Connects to a remote or in-line blower
Blower Model
Remote blower 1000 CFM VTR1030W
Remote blower 600 CFM VTN630W
Remote blower 1300 CFM VTR1330W
In-line blower 600 CFM VTI610W
In-line blower 1000 CFM VTI1010W
White to white
Black to black
Green to green
or bare wire
1
2