Installation Guide

Page. 15
Blower motor installation
Blower and circuit breaker ratings
9 CAUTION
To reduce the risk of fire and electric shock, install this
range hood only with the blowers listed in the
Ventilation Planning Guide.
NOTE: Cutting the plug of the blower will void the
warranty or eligibility for return or exchange.
Integral blower installation
Integral blower models are integrated into the hood at the
time of installation. Integral blowers should be installed
after the hood is mounted to the wall. For complete
installation instructions, see the instructions supplied with
the blower unit.
Installing the integral blower
1. The blower is attached to the hood using weld studs
on the mounting plate. Guide the motor mounting
plate over the studs.
2. Attach four (4) nuts (included with hood) to the weld
studs. Tighten nuts with an 11/32'' nut driver to secure
the blower to the hood.
Integral blower In-line blower Remote blower
VTN630W VTN1090W VTI610W VTI1010W VTR630W VTR1030W VTR1330W
HPCN36WS
Amps 4.0 7.4 5.9 7.8 5.9 7.8 11.3
Watts 480 888 708 936 708 936 1,356
Voltage 120 120 120 120 120 120 120
Dedicated breaker 15 15 15 15 15 15 15
HPCN48WS
Amps 4.6 8.0 6.5 8.4 6.5 8.4 11.9
Watts 552 960 780 1,008 780 1,008 1,428
Voltage 120 120 120 120 120 120 120
Dedicated breaker 15 15 15 15 15 15 15