Design Guide
BLOWER AND DUCT SELECTION GUIDE
PLANNING INFORMATION
VENTILATION | PLANNING INFORMATION
1.800.735.4328 | THERMADOR.COM
211
WALL
HOODS
BLOWER INFORMATION HOOD INFORMATION
Type Model # CFM
Total Amps
(120V, 60Hz)
Roofplate
Required
Duct Size
at Blower
Transition
w/Backdraft
Damper
Duct
Size at
Discharge
Discharge
Direction
PROFESSIONAL SERIES
PH__GS
36" / 42" / 48" / 54" / 60"
Remote
(Use Roof Jack
RJ310)
VTR630P 600 12.1 RFPLT600P 6-Inch
Included 10-Inch
Vertical,
Horizontal
VTR1030P 1000 14.0 RFPLT1000P 10-Inch
VTR1330P 1300 17.5 RFPLT1000P 10-Inch
Inline
(Use Wall Cap
WC10)
VTI610P 600 12.1 — 6-Inch
VTI1010P 1000 14.0 — 10-Inch
PH__GS
36" / 42" / 48" / 54"
Integrated
(Use Wall Cap
WC10)
VTN630N 600 10.3 — 10-Inch
Included 10-Inch
Vertical,
Horizontal
VTN1030N 1000 13.6 — 10-Inch
PH60GS 60"
(Integrated Blower Option Coming Soon)
Integrated
PH__HS
30" / 36" / 48"
Remote
(Use Roof Jack
RJ310)
VTR630P 600 6.9 RFPLT600P 6-Inch
Included 10-Inch Horizontal
VTR1030P 1000 8.8 RFPLT1000P 10-Inch
VTR1330P 1300 12.3 RFPLT1000P 10-Inch
Inline
VTI610P 600 6.9 — 6-Inch
VTI1010P 1000 8.8 — 10-Inch
Integrated
(Use Wall Cap
WC10)
VTN630N 600 5.0 — 10-Inch
VTN1030N 1000 8.4 — 10-Inch
HPWB30FS
30" (Use Recirculation Kit RECIRC30FS)
Integrated Included 600 3.4 — 10-Inch Included 10-Inch Vertical
HPWB__FS
36" / 48"
Integrated Included 1000 10.2 — 10-Inch Included 10-Inch Vertical
MASTERPIECE
®
SERIES
HMWN30FS
30"
(Use Recirculation Kit RECIRC30FS)
Remote
(Use Roof Jack
RJ310)
VTR630P 600 4.3 RFPLT600P 6-Inch
Included 10-Inch Vertical
VTR1030P 1000 7.8 RFPLT1000P 10-Inch
VTR1330P 1300 12.3 RFPLT1000P 10-Inch
Inline
VTI610P 600 5.8 — 6-Inch
VTI1010P 1000 7.6 — 10-Inch
Integrated VTN600N 600 4.6 — 10-Inch
HMWN__FS
36" / 48"
(Use Recirculation Kit RECIRC36FS
for 36" only)
Remote
(Use Roof Jack
RJ310)
VTR630P 600 4.3 RFPLT600P 6-Inch
Included 10-Inch Vertical
VTR1030P 1000 7.8 RFPLT1000P 10-Inch
VTR1330P 1300 9.2 RFPLT1000P 10-Inch
Inline
VTI610P 600 5.8 — 6-Inch
VTI1010P 1000 7.6 — 10-Inch
Integrated
VTN600N 600 4.6 — 10-Inch
VTN1000N 1000 8.8 — 10-Inch
HMWB__FS
30" / 36"
(Use Recirculation Kit RECIRC30FS
or RECIRC36FS)
Integrated Included 600 3.4 — 10-Inch Included 10-Inch Vertical
BLOWER CONNECTOR CABLE
- 25 ft. Blower Connector Cable for use with the following Inline and Remote blowers: VTR630P, VTR1030P, VTR1330P, VTI610P VTI1010P*
EXTNCB25
*Cannot be used with HMWN30FS or HMWN48FS