Installation guide
REMOTEVENTILATOR
INSTALLATION
HMWN
30/36/48
Series
Hood:
The
hood
is
designed
to
work
with
Thermador’s
remote
and
in
line
ventilator
rated
with
a
maximum
corrent
absorbtion
of
8.5
Amp.
(see
list
under
paragraph
“Parts
Not
Included
with
your
Hood”)
For
installation
instructions
see the
instructions
supplied
with
the
ventilator
unit.
Wiring
the
Hood
with
a
Remote
or
in
line
Ventilator:
Warning:
Turn
off
electricity
at
the
service
panel
before
wiring
the
unit.
1.
Remove
the
j-box
cover
as
shown
in
Figure
8.
2.
Remove
cover
T
from
the
j-box.
3.
Remove
the
2
knockouts
and
install
1/2”
conduit
connectors.
4.
Run
black,
white,
and
green
wires
(#14AWG)
in
1/2”
conduit
5.
Connect
black,
white,
and
green
Power
supply
conduit
To
Remote
Ventilator
To
Control
Panel
Connector
in
the
internal
body
panel
SS
53
PIG
TAIL
Figure
8
Ground
wire
from
8
Remote
Ventilator
green
wires
from
power
supply
to
black,
white
and
green/
yellow
wires
in
j-box
respectively.
6.
Connect
wire
clamp
to
“pigtail”
as
shown
in
Figure
12.
Insert
“pigtail”
wire
into
j-box
and
fix
wire
clamp
to
j-box
using
nut
supplied
with
clamp
V.
7.
Run
five
wires
(14AWG)
in
1/2”
conduit
from
the
remote
blower
to
the
second
conduit
connector.
8.
Connect
the
wires
coming
from
pigtilto
the
wires
from
external
blower
according
with
the
following
table.
9,
Close
junction
box
cover.
Check
that
all
ligth
bulbs
are
secure
in
the
soclets.
Install
filters.
Turn
power
on
at
service
panel,
and
check
ligths
and
blower
operation
per
Care
&
Use section
of
this
manual.
ELECTRICAL
PIGTAIL
DETAILS
The
pigtail
is
configured
to
be
connected
as
is
described
in
the
following
table.
FUNCTION
COLOR
Speed
1
Red
Speed
2
Blue
Speed
3
Orange
Speed
4
Brown
Common
White