Installation Guide
Installation Instructions English | 19 |
5. Carefully pull the top part of the extension upwards.
Screw the left and right sides of the extension to the
mounting bracket with the supplied stainless screws.
6. From inside of hood, screw the supplied
5
⁄8’’ (16 mm)
sheet metal screws through the holes on each side
and along the front into bottom of the extension.
Screw quantity is dependent on hood size.
Recirculating Kit (optional)
When used in recirculation mode, To Reduce the Risk of
Fire and Shock use only conversion kit Model RECHMCB.
If it is not possible to vent cooking fumes and vapors to
the outside, the hood can be used in the non-vented
(recirculating) version, using the recirculating kit .
Fumes and vapors are recycled through the round grid.
See optional accessories section.
1. Assembletheairdeectorwiththeductcoverbracket
using (4) 4.2 x 8 mm screws.
C
B
A
A. Mounting screws
B.Airdeector
C. Duct cover bracket
2. Measurefromthebottomoftheairdeectortothe
bottom of the hood outlet.
X
A
C
B
D
E
A.Airdeector
B. Vent clamp
C. X = length to cut vent duct
D. Vent duct
E. Exhaust outlet
3. Cut the duct to the measured size “X.”
4. Removetheairdeector.
5. Slidetheductontothebottomoftheairdeector.
6. Placetheassembledairdeectorandductoverthe
exhaust outlet from the hood.
7. Reassembletheairdeectortotheductcoverbracket
with the four assembly screws.
8. Useducttapeorventclampstosealthedeectorand
the exhaust outlet from the hood.