Installation Guide
7
WARNING: A qualified service person must install heater. Follow all local codes.
You must provide propane gas and propane cylinder. Use a standard 10lb. or
20lb. propane cylinder.
Use this heater only with a propane vapor withdrawal supply system. See
chapter 5 of the standard for storage and handling of liquefied petroleum Gas,
ANSI/NFPA58. Your local library or fire department should have this book.
The minimum permissible gas supply pressure of 11 W.C. is required for purpose
of input adjustment.
The minimum hourly of 15,000BTU is required input rating for a heater for
automatic operation at ratings less than full input rating.
The pressure regulator and hose assembly supplied with the appliance must be
used.
The installation must conform with local codes, or in the absence of local codes,
with National Fuel Gas Code, ANSI Z223.1.
A dented, rusted or damaged propane cylinder may be hazardous and should be
checked by your cylinder supplier. Never use a propane cylinder with a damaged
valve connection.
The propane cylinder must be constructed and marked in accordance with the
specifications for LP gas cylinders of the U.S. Department of Transportation
(DOT).
Never connect an unregulated propane cylinder to the heater.
1) Mount the heater to the bracket using the screws provided. (see figure 2). Some
models come pre-mounted and require no attention to assembly.
Figure 2 – Mounting heater to bracket