Installation Guide
5
upon re-assembly.
This heater is designed to operate with a standard 10lb. or 20lb. propane cylinder
with approved cylinder connection.
The gas manifold supply pressure must be regulated at 11 inches of water
column utilizing an approved regulator. The minimum inlet gas supply pressure
for the purpose of input adjustment is 11 inches Water Column. The maximum
inlet gas supply pressure is 11 inches Water Column. LP Gas supply cylinder is
not provided with the appliance.
The cylinder must be provided with a shut off valve termination in an LP-gas
supply cylinder valve outlet specified, as applicable, for connection No.510 in the
standard for compressed gas cylinder valve outlet and inlet connections,
ANSI/CGA-V-I, or connection No.600 in the compressed gas association’s limited
standard cylinder valve outlet connection for propane-small valve series.
The cylinder supply system must be arranged for vapor withdrawal;
The cylinder used must include a collar to protect the cylinder valve if a
connection No.600 is used
ONLY CYLINDERS MARKED "PROPANE" MUST BE USED.
LP-gas supply cylinder to be used must be:
(a) Constructed and marked in accordance with the Specifications for LP-gas cylinders
of the U.S. Department of Transportation (DOT); or the Standard for Cylinders, Spheres
and Tubes for Transportation of Dangerous Goods and Commission, CAN/CSA-B339,
as applicable;
(b) Provided with a listed overfilling prevention device; and
(c) Provided with a cylinder connection device compatible with the connection for the
appliance.
QUALIFIED INSTALLING AGENCY
Only a qualified agency should install and replace gas piping, gas utilization equipment
or accessories, and repair and equipment servicing. The term “qualified agency” means
any individual, firm, corporation, or company that either in person or through a
representative is engaged in and is responsible for:
a) Installing, testing, or replacing gas piping or
b) Connecting, installing, testing, repairing, or servicing equipment; that is experienced in
such work; that is familiar with all precautions required; and that has complied with all the
requirement of the authority having jurisdiction