Installation Guide

12
CLEANING EXTERIOR
Use a soft cloth dampened with a mild soap and water mixture.
Wipe the cabinet to remove dust.
1) Use a soft cloth dampened with a mild soap and water mixture.
2) Wipe the cabinet to remove dust.
TROUBLE SHOOTING
WARNING: If you smell gas:
1) Open the window and door immediately.
2) Shut off gas supply.
3) Do not try to light any appliance.
4) Do not touch any electrical switch; do not use any phone in your building.
5) Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
6) If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning
supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or
textiles, etc., create fumes. These fumes may mix with combustion air and create odors.
WARNING: Only a qualified service technician should service and repair heater
NO.
PROBLEM
POSSIBLE CAUSE
REMEDY
1
-When igniter button is
pressed in there is no spark
at igniter.
-- Igniter electrode is positioned
wrong or broken.
-- Igniter electrode is not
connected to Igniter cable.
-- Igniter cable is pinched or wet.
-- Broken igniter cable.
-- Bad piezo igniter.
--- Replace igniter
--- Reconnect igniter cable.
--- Free igniter cable if pinched by
any metal or tubing. Keep igniter
cable dry.
--- Replace igniter cable.
--- Replace piezo igniter.
2
-When igniter button is
pressed in there is a spark
at igniter but no ignition.
-- Gas supply is turned off or
equipment shutoff valve is closed.
-- Control knob not fully pressed in
while pressing igniter button.
-- Air in gas lines when installed.
-- Igniter is blocked.
-- Gas regulator setting is not
correct.
-- Control knob not in PILOT
position.
-- Depleted gas supply (propane).
--- Turn on gas supply or open
equipment shutoff valve.
--- Fully press in control knob
while pressing igniter button.
--- Continue holding down control
knob. Repeat igniting operation
until air is removed.
--- Clean igniter (see Care and
Maintenance) or replace igniter
assembly.
--- Replace gas regulator.
--- Turn control knob to LIGHT
position.
--- Contact local propane/LP gas