Installation Guide

10
UNIT OPERATION
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may
result causing property damage, personal injury or loss of life.
Before Turning Gas Supply On:
1. Your heater was designed and approved for indoor use only. Do NOT use in poorly
ventilated areas, or any other tightly enclosed area.
2. Make sure surrounding areas are free of combustible materials, gasoline, and other
flammable vapors or liquids.
3. Ensure that the flow of combustion and ventilation is not obstructed
4. Be sure all gas connections are tight and there are no leaks.
5. Be sure the cylinder cover is clear of debris.
6. Be sure any component removed during assembly or servicing is replaced and
fastened prior to starting.
7. Be sure the heater is level prior to lighting and during use. Place heater on a level
surface such as a table or any other non-combustible solid level surface.
Before Lighting
1. Heater should be thoroughly inspected before each use and by a qualified service
person at least annually.
2. If relighting a hot heater, always wait at least 5 minutes
3. Inspect the hose assembly for evidence of excessive abrasion, cuts, or wear.
Suspected areas should be leak tested. If the hose leaks, it must be replaced prior to
operation. Only use the replacement hose assembly specified by manufacturer.
Lighting
1. Open valve on LP cylinder
2. While in off position depress control knob slightly and turn control knob
counterclockwise to the Ignition position.
3. Depress control knob while pressing the igniter button. (See figure 5)
4. After burner is lit, keep the control knob pressed for 5 seconds before adjusting to
desired setting, turn to ON position.
5. To shut down heater turn control knob to igniter position, depress slightly and turn to
OFF.
6. After shut down, user must wait 5 minutes prior to re-igniting.
7. Close valve on LP cylinder.
Shut Down
1. Press control knob and continue to turn it clockwise to OFF position.
2. Turn propane cylinder valve clockwise to OFF and disconnect regulator when heater
is not in use.