Installation Guide

9
When the heater is to be stored indoors, the connection between the propane supply
cylinder(s) and the heater must be disconnected and the cylinders) removed from the
heater and stored in accordance with Standard for the Storage and Handling of
Liquefied Petroleum Gases, ANSI/NFPA 58 and Natural Gas and Propane Installation
Code, CSA B149.1
VERIFY THE FOLLOWING PRIOR TO CONNECTING OR CHANGING THE LP
CYLINDER
A leak test should be performed with soapy water whenever connecting a new
cylinder.
Never use a match to test for leaks.
If disassembly is required, a leak test should be performed with soapy water
upon re-assembly.
Never use a match to test for leaks.
VERIFY THE FOLLOWING MINIMUM INSTALLATION CLEARANCES PRIOR TO
USING HEATER
Minimum Clearance from Combustibles and Propane
Containers
Distance from Wall
3 Ft.
Distance from Floor
1 Inch
Distance from Ceiling
8 Ft.
Distance from Propane Container
6 Ft. (1.83m)