TABLE OF CONTENTS About Us………………………….….….…1 Product Specifications……………………1 Important Safety Information…………….2 Product Features………………………….4 Installation Checklist……………………...5 Water Vapor……………………………….7 Air for Combustion…………………….….8 Determining Fresh Air Flow……………...9 Installation Considerations…………………11 Connecting to Gas Supply..........................15 Unit Operation……………………………….17 Care and Maintenance…...........................20 Troubleshooting…………...........................
IMPORTANT SAFETY INFORMATION IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning. Only a qualified installer, service agent, or local gas supplier may install and service this product.
CAUTION: Two gas line installations at the same time are prohibited. The access plate to the switching means shall not be opened while the heater is in operation. vapors are used or stored under dusty conditions. 8. Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.
QUALIFIED INSTALLING AGENCY Only a qualified agency should install and replace gas piping, gas utilization equipment or accessories, repair and service the heater.
INSTALLATION CHECKLIST Share this checklist with your professional installer Manifold Pressure and Nominal Inlet Pressure for appropriate gas type o Using Natural Gas: Minimum Inlet Pressure (W.C): 6” Manifold Pressure (W.C.): 5.2” Nominal Input Pressure (W.C.): 7” o Using Propane Gas: Minimum Inlet Pressure (W.C): 8” Manifold Pressure (W.C.): 6” Nominal Input Pressure (W.C.
Preparing for Installation Before beginning assembly or operation of the product, make sure all parts are present. Compare parts with package contents list and diagram above. If any part is missing or damaged, do not attempt to assemble, install or operate the product. Contact customer service for replacement parts.
UNPACKING 1. Remove heater from carton. 2. Remove all protective packaging applied to heater for shipping. 3. Check heater for any shipping damage. If heater is damaged, promptly inform dealer where you purchased heater. 4. Remove thread protective cup on the gas inlet pipe underneath the heater. 5. Install a D size battery. Battery must be removed if the heater is not in use for an extended period of time.
AIR FOR COMBUSTION AND VENTILATION WARNING: This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. Read the following instructions to ensure proper fresh air for this and other fuel-burning appliances in your home. space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.
DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with door less passageways or ventilation grills between the rooms. 1. Determine the Volume of space in cubic feet Length X Width X Height = ___________________ cu. Ft. (Including adjoining rooms with door less passageways or ventilation grills between rooms) Example: 24’ (L) X 16’ (W) 8’ (H) = 3,072 cu.
WARNING: If the area in which the heater may be operated does not meet the required volume for indoor combustion air, combustion and ventilation air shall be provided by one of the methods described in the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the International Fuel Gas Code, or applicable local codes. Ventilation Air from Inside Building This fresh air would come from an adjoining unconfined space.
INSTALLATION CONSIDERATIONS This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source. WARNING: A qualified service person must install heater.
Figure 6 – Minimum Clearance Above Combustible Flooring. Figure 7 – Minimum Clearance Above Combustible Flooring with Noncombustible Material Installed at Base of Fireplace. The gas log heater must be installed at least 1 3/8” above any combustible flooring material, such as carpeting or tile, which is closer than 14” to the base of the fireplace. The minimum distance must be maintained from the top surface of carpeting, tile, etc. See Figure 6.
National Fuel Gas Code. When the gas logs are operated with the damper open, Non-Combustible material and minimum mantel requirements do not apply. Note: When installing your log set as a vented installation the damper clamp (Not Provided in hardware) must be used. Air Door Setting the Air Door to the appropriate gas type being supplied to the log set is important, as it improves the color and appearance of the flame. The Air Door is located on the bottom of the log set heater.
Loosen this screw. Then, with your screwdriver still contacting the screw, slide/rotate the cylinder towards the NG (Natural Gas) side until it cannot slide any further. Once done, you will tighten the screw on the cylinder, then seal the air shutter cover again. For more information please visit our website www.thermablaster.com. You can contact us at 877-670-8428 or via email service@thermablaster.com.
Log Placement Ensure that your heater’s logs are placed as shown below. It’s important that your logs do not cover burner holes, as this can lead to sooting and an overall drop in the performance of your heater. Logs should be placed sequentially, from lowest to highest, as the numbering indicates. There are grooves on many of the logs that allow for simple placement and help to prevent the logs from shifting positions.
CONNECTING TO GAS SUPPLY WARNING: A qualified service technician must connect heater to gas supply. Follow the heater specification and all local codes. Wrong gas supply may result improper operation, or damage on your heater, property or/and personal body. WARNING: This appliance requires a 3/8-inch UNF (Unified National Fine) inlet connection to the pressure regulator. External regulator Propane/LP supply tank WARNING: Never connect heater to private (non-utility) gas wells.
CAUTION: Two gas lines installation at the same time is forbidden. Do not the open cover while the heater is running. CAUTION: To avoid gas leakage at the inlet of appliance regulator, a qualified installer or service technician must use steel or metal hex plug with sealant. Changing from Liquid Propane to Natural Gas supply: 1.
UNIT OPERATION FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. 1. When lighting the pilot, follow these instructions exactly. 2. BEFORE LIGHTING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. 3. Use only your hand to push in or turn the gas control knob. Never use tools.
Ignition Process: 1. During the first seasonal operation, set the Control Knob to Pilot, then hold down on the Control Knob for 3-5 minutes. This allows the air in the manifests to clear completely. During normal operation, you will only need to hold the Control Knob down on Pilot for about 5 seconds. 2. With the Control Knob set to Pilot, push down on both the Igniter Button and the Control Knob simultaneously until ignition can be heard.
Figure 10 – Control Panel Figure 11 – Pilot System Figure 12 – Pilot Blue Flame 20
CARE AND MAINTENANCE WARNING: Turn off heater and let cool before servicing CAUTION: You must keep control areas, burner, and circulating air passageways of the heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service technician. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc. Installation and repair should be done by a qualified service person.
TROUBLESHOOTING WARNING: If you smell gas: Open the window and door immediately. Shut off gas supply. Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department. IMPORTANT: Operating heater where impurities in air exist may create odors.
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION Igniter electrode is positioned wrongly. Cables between switch, battery pack, igniter and igniter electrode may be loose, pinched, wet or broken. Bad igniter No battery or battery used out. Gas supply is turned off or equipment shutoff valve is closed. Control knob not fully pressed in while pressing igniter button. Air in gas lines when installed. Reposition igniter electrode.
Heater produces a whistling noise when burner is lit. Heater produces a clicking/ ticking noise just after burner is lit or shut off. White powder residue forming within burner box or on adjacent walls or furniture. Heater produces unwanted odors. Heater shuts off in use (ODS operates). Gas odor during combustion Unexpected moisture/condensation noticed on windows.
ILLUSTRATED PARTS (Model: GLDF18T-VF) 25
PARTS LIST (Model: GLDF18T-VF) Code Description Code Description 1 Ignition button 25 ODS fixing bracket 2 Spring 26 Pilot burner 3 Button seat 27 NG ODS 4 Guiding rod 28 Four-way joint 5 Ignition button seat 29 Four-way joint insert 6 Igniter micro switch 30 Pulse igniter 7 Screw 31 Frame assembly 8 Gas source detecting valve 32 LP ODS 9 Pipe transition joint 33 Chamber spacer 10 Nozzle seat 34 Battery pack 11 LPG Nozzle 35 Bottom Strengthen strip No.
Questions about installation and initial operation should be directed to your installer. For all other concerns and questions, please reach out to our customer service team at 1-877-670-8428, by email at service@thermablaster.com, or visit www.thermablaster.com Annual Service Schedule Service Performed Service Date Please register your product online at www.thermablaster.