2.5 Testing
Verify the wiring connections.
WARNING! ONLY CONNECT THE WHITE WIRE
TO THE CONTROL IF IT IS WIRED IN A CIRCUIT THROUGH AN
ELECTRIC DAMPER, OTHERWISE TRANSFORMER DAMAGE
MAY RESULT.
After checking the wiring, this short test will confirm proper
hook-up.
1. Install front cover of the DEH 3000R; connect the top first,
then the bottom.
2. Plug in the Ultra-Aire dehumidifier. The DEH 3000R should
power up.
3. Turn the DEH 3000R ON by pressing the ON/OFF button.
4. Verify dehumidification operation by adjusting the RH
“SETPOINT” to below the “%RH” reading on the display.
Use the down “RH button. Confirm Ultra-Aire fan and
compressor operation. Both should be ON now.
Increase the RH SETPOINT” on the display to well above the
“%RH” reading on the display. Press the “RH up arrow to
increase the RH SETPOINT”.
After running the dehumidifier compressor the DEH 3000R
applies a 10 minute restart lockout on all functions. You will
have to wait for the restart lockout to expire.
5. Verify FAN-only operation:
a. Check the VENT” mode on the display, it will either
be “CLOSED” or “OPEN. If it is CLOSED go to the
next step. If it is OPEN”, press and hold the VENT”
key until OPENashes on the display, release the key
and then press it one more time. “OPEN will change to
“CLOSED”. Don’t touch the keys for several seconds until
it stops flashing.
b. Press and hold the FAN” button until AUTO” begins
flashing on the display, release it, and then press it again
to switch the fan to the ON” setting.
c. Confirm that the Ultra-Aire fan is ON. Ultra-Aire
compressor must be OFF. Ventilation damper (if used)
should be CLOSED.
6. Verify optional VENT operation (if electric damper is installed):
a. Press and hold the FAN” button until ON” flashes on
the display.
b. Release the “FAN” button, then press it again to switch
fan operation to AUTO.
c. Press and hold the VENT” button until “CLOSED”
flashes on the display.
d. Release the “VENT button, then press it again to switch
vent mode to OPEN”.
e. Confirm that the Ultra-Aire fan is ON. Ventilation damper is
OPEN. Ultra-Aire compressor must be OFF.
f. Press and hold the VENT” button until the OPEN”
flashes on the display.
g. Release the “VENT button, then press it again to switch
vent mode to CLOSED.
WARNING! DO NOT MAKE ANY OTHER
CONNECTIONS OR TRANSFORMER DAMAGE MAY RESULT.
7. Verify any additional optional control operations such as fan
interlock or A/C lockout.
8. Proceed to the Operation section.
2.6 Troubleshooting
FOR THE HVAC PROFESSIONAL:
n
No display on initial start up.
Note: This is often the result of a drained capacitor. The
capacitor will recharge once power is applied or re-applied to
the unit.
Verify unit has power.
Turn unit off then on.
Disconnect the unit from power source then re-apply
power to the unit. Display should now operate.
n
Function not working properly.
Verify wiring.
Verify voltage with voltmeter.
n
Dehumidifier not working properly.
– See chart below:
Wire connections Operation
Yellow & Blue Fan & Compressor
Yellow & Green Fan Only
5