- Therma-Stor Ultra-Aire 100V OWNER'S MANUAL

FOR HVAC INSTALLER ONLY AND HOMEOWNER
The ventilation indicator
O
will be displayed whenever the unit
is ventilating. The fan operation indicator
O
will also be lit.
There are three damper operation modes, “OPEN
HOLD,
CLOSED HOLD” and PROGRAM” (denoted by ON TIME”
“OFF TIME. Refer to section 3.8). With the damper in the
OPEN
HOLD mode, the damper will be open and the fan of
the system will be operating in order to introduce fresh air into
the space. Use this mode for continuous fresh air ventilation. The
fan is always on when the damper is open. When in “CLOSED
HOLD mode, the damper will not open and the system will not
ventilate.
When in the program mode, the control will operate the damper
and fan (ventilate) according to the programmed ventilation
schedule (See Section 3.8).
To set the damper operation:
1. Press the VENT button. The current setting will begin to
ash on the display. Release the button.
2. Press the VENT button again to toggle between OPEN,
CLOSED and PROGRAM.
3. Leave the control alone for 10 seconds to select the indicated
damper mode and return to HOME.
5.3H Intermittent or Programmed Ventilation
The system will operate the ventilation function according to the
current ventilation program. The control needs to be programmed
to turn the ventilation function on and off at the desired intervals.
This is done by programming the ventilation timer.
There are two programs available for ventilation Monday
through Friday. There are also two programs for Saturday and
Sunday. No other choice of days is available.
Each program has:
A “START” time of day when the ventilation schedule
begins.
An “OPEN FOR” duration for the amount of time the
damper stays open in 5 minute intervals, from 0 to 60.
A “CLOSED FOR” duration which closes the vent for a
specified time in 5 minute intervals from 0 to 60.
Example:
1. Press “PROGRAM ENTER” button. The following menu
appears:
2. Using the up/down RH buttons, select “PROGRAM. The
following menu appears:
You can select from:
“MON-FRI or “SAT-SUN” for separate weekday/weekend
schedules or “MON-SUN” which gives you equal weekday/
weekend schedules.
Menu when you select “MON-FRI” or SAT-SUN”:
1. Enter the starting time for weekdays using the up/down
RH keys to change the time.
This example shows the damper in “PROGRAM” mode
(denoted by the schedule 15 minutes on, 5 minutes off).
The status of the damper is show here.
is open, blank is closed.
14
Ultra-Aire 100V Installer’s & Owner’s Manual
15
Ultra-Aire 100V Installer’s & Owner’s Manual