- Therna-Stor Production Santa-Fe Rx Free-Standing Dehumidification Installer's & Owner's Manual

Table of Contents
1. Specifications .......................................................................... 2
2. Installation .............................................................................. 2
2.1 Location .............................................................................. 2
2.2 Electrical Requirements ..................................................... 3
2.3 Condensate Removal ......................................................... 2
2.4 Optional Reservoir Container .............................................. 3
2.5 Safety Overflow Switch ...................................................... 3
3. Operation ................................................................................. 3
3.1 Top Removal ...................................................................... 3
3.2 Humidity Control Adjustment .............................................. 3
3.3 Power Switch ......................................................................3
4. Maintenance ........................................................................... 3
4.1 Air Filter ............................................................................. 3
4.1A Filter Options ................................................................. 4
4.1B Optional Filter Test ........................................................ 4
5. Service ................................................................................... 4
5.1 Warranty ............................................................................ 4
5.2 Technical description ......................................................... 4
5.3 Troubleshooting ................................................................. 4
5.4 Refrigerant Charging .......................................................... 5
5.5 Blower Replacement .......................................................... 5
5.6 Compressor/Capacitor Replacement .................................. 5
5.6A Replacing A Burned Out Compressor ...................................... 6
5.6B Replacing a Compressor - Nonburn Out .................................. 6
5.7 Humidity Control ................................................................ 6
5.8 Defrost Thermostat ............................................................ 6
5.9 Condensate Pump .............................................................. 6
5.10 Relay................................................................................ 6
5.11 Low Pressure Control ....................................................... 6
Wiring Diagram ............................................................................ 7
Service Parts List ........................................................................ 8
Filter Frame Assembly ................................................................ 9
Set-Up Instructions ....................................................................10
Laminate Top Kit .......................................................................11
Warranty .................................................................................... 12
Read the installation, operation and maintenance instructions
carefully before installing and using this unit. Proper adherence to
these instructions is essential to obtain maximum benefit from
your Santa Fe Rx Dehumidifier.
1. Specifications
Part Number: 4023673
Model: Santa Fe Rx Dehumidifier
Electrical: 110-120 VAC, 6.3 Amps, grounded
Capacity: 86 pints/day @ 80°F, 60% RH
Operating Temp. 65°F min., 100°F max.
Range:
Air Flow: 230 CFM @ 0.0" WG
Refrigerant Charge: 1 lbs., 14 oz. R-22
Unit Size: 20” D x 23” W
37
1/
2
” H w/top
Weight: 130 lbs
2. Installation
2.1 Location
The Santa Fe Rx can be installed in a variety of locations to meet
the owner’s needs as listed below. In all cases, keep the following
cautions in mind:
1. It is designed to be installed INDOORS ONLY.
2. If used near a pool or spa, be certain there is NO chance the
unit could roll into the water or be splashed and that it is
plugged into a GROUND FAULT INTERRUPTER.
3. DO NOT use the Santa Fe as a bench or table.
4. Avoid discharging the air directly at people, especially in pool
areas.
Consider the following points when choosing a location for
your Santa Fe Rx:
1. The Santa Fe Rx is most effective if it is centrally located in the
space to be dehumidified.
2. It is designed to be placed with its back 3” or more from a wall
(the air outlet is located at the lower portion of the back). This
will reduce noise and the likelihood that discharge air will blow
directly at someone.
3. The water removed by the APD will be pumped through the
white 20’ long hose coming from under its base. The hose
(about the diameter of a TV coaxial cable) must be routed to
a drain or outside. It can pump 15’ above the unit and can be
extended (see section 2.3).
4. The top can serve as a light duty table (maximum load: 20 lbs.),
but it must be removed periodically to check the air filter.
2.2 Electrical Requirements
The Santa Fe Rx plugs into a common grounded outlet on a
15 Amp circuit. It draws between 6 and 7 Amps under normal
operating conditions. If used in a wet area (pool, spa room, or
basement prone to flooding), a ground fault interrupter protected
circuit is required.
2.3 Condensate Removal
The Santa Fe Rx is equipped with a condensate pump to remove
the water that is condensed during dehumidification. This allows
the water to be discharged to a distant location, or to be pumped
up to 15’ above the Santa Fe Rx.