1 Specifications
Part No. 4024920
Power 110-120 Vac, 7.4 amps; 851 watts
Water 133 pints/day @ AHAM (80°F, 60%)
Removal 240 pints/day @ saturation
30 gal/day maximum @ saturation
Refrigerant 1 lbs., 14 oz. R-22
Charge
Blower 265 CFM
Internal Condensate Pump with 20 lift,
30’ vinyl hose
Operating 33°F to 105°F
Range
Filters 16” x 20”
Standard 2” Pleated Media 30%* MERV-6
Optional 2” Pleated Media 30%* MERV-8
Optional 2” Pleated Media 65%* MERV-11
Optional 4” Mini-Pleat Media 95%* MERV-14
Duct Intake – 12” Flex-Duct
Options Supply – 10” Lay-Flat
Warranty Five years;
First year 100% of Parts and Labor
Second-fifth year 100% of Parts of sealed
refrigeration system.
Dimensions:
Cabinet w/Cart Shipping
Width 20” 24-1/4” 27-1/2”
Height 40” 40” 45-1/2”
Depth 18-1/4” 21-3/8” 22”
Weight 131 lb 160 lb
2 Operation
2.1 Transporting the Phoenix
The Phoenix 200 MAX must always be upright when
transported by vehicle. It may be tipped on to its handle
and back for loading and moving by hand.
2.2 Location
Note the following precautions when locating the Phoenix
200 MAX:
It is designed to be used INDOORS ONLY.
If used in a wet area, plug it into a GROUND FAULT
INTERRUPTER.
DO NOT use the Phoenix 200 MAX as a bench or table.
It must always be used in the upright position.
Read the operation and maintenance instructions
carefully before using this unit. Proper adherence to these
instructions is essential to obtain maximum benefit from
your Phoenix 200 MAX dehumidifier.
Table of Contents
Introduction ................................................................1
1. Specifications ........................................................2
2. Operation .............................................................2
2.1 Transporting the Phoenix 200 MAX ...................2
2.2 Location .........................................................2
2.3 Electrical Requirements ...................................3
2.4 Condensate Removal .......................................3
2.5 Ducting ...........................................................3
2.6 Power Switch ..................................................3
2.7 Pump Purge Switch ..........................................3
2.8 Hour Meter .....................................................3
2.9 Defrost Control Adjustment ..............................
3
2.10 Low Pressure Control .....................................4
3. Maintenance .........................................................4
3.1 Air Filter ..........................................................4
3.2 Storage ..........................................................4
4. Service .................................................................4
4.1 Warranty .........................................................4
4.2 Technical Description .......................................4
4.3 Troubleshooting ...............................................5
4.4 Refrigerant Charging ........................................5
4.5 Blower Replacement ........................................5
4.6 Compressor/Capacitor Replacement ................6
4.6A Checking Compressor Motor Circuits .........6
4.6B Replacing a Burned Out Compressor .........6
4.6C Replacing a Compressor- Non-Burn Out ......7
4.7 Defrost Thermostat & Timer .............................7
4.8 Condensate Pump ...........................................7
4.9 Gravity Drain Option .........................................
7
4.10 Relay ............................................................
7
5. Wiring Diagram .....................................................8
6. Service Parts List ..................................................
9
7. Warranty .............................................................11
Serial No. ___________________________
Purchase Date ______/______/_____
Dealer’s Name ___________________________________