User`s manual

73
5. The other combination to make as “On line” can have read / write work as
normal.
Below is a table listing of possible RAID migration schemes:
To
From
RAID 0 RAID 5 RAID 6
RAID
0
[OFFLINE]
[RAID 0] HDDx2 to [RAID 0] HDDx3
[RAID 0] HDDx2 to [RAID 0] HDDx4
[RAID 0] HDDx2 to [RAID 0] HDDx5
[RAID 0] HDDx2 to [RAID 0] HDDx6
[RAID 0] HDDx2 to [RAID 0] HDDx7
[RAID 0] HDDx3 to [RAID 0] HDDx4
[RAID 0] HDDx3 to [RAID 0] HDDx5
[RAID 0] HDDx3 to [RAID 0] HDDx6
[RAID 0] HDDx3 to [RAID 0] HDDx7
[RAID 0] HDDx3 to [RAID 0] HDDx8
[RAID 0] HDDx4 to [RAID 0] HDDx5
[RAID 0] HDDx4 to [RAID 0] HDDx6
[RAID 0] HDDx4 to [RAID 0] HDDx7
[RAID 0] HDDx4 to [RAID 0] HDDx8
[RAID 0] HDDx5 to [RAID 0] HDDx6
[RAID 0] HDDx5 to [RAID 0] HDDx7
[RAID 0] HDDx5 to [RAID 0] HDDx8
[RAID 0] HDDx6 to [RAID 0] HDDx7
[RAID 0] HDDx6 to [RAID 0] HDDx8
[RAID 0] HDDx7 to [RAID 0] HDDx8
[OFFLINE]
[RAID 0] HDDx2 to [RAID 5] HDDx3
[RAID 0] HDDx2 to [RAID 5] HDDx4
[RAID 0] HDDx2 to [RAID 5] HDDx5
[RAID 0] HDDx2 to [RAID 5] HDDx6
[RAID 0] HDDx2 to [RAID 5] HDDx7
[RAID 0] HDDx3 to [RAID 5] HDDx4
[RAID 0] HDDx3 to [RAID 5] HDDx5
[RAID 0] HDDx3 to [RAID 5] HDDx6
[RAID 0] HDDx3 to [RAID 5] HDDx7
[RAID 0] HDDx3 to [RAID 5] HDDx8
[RAID 0] HDDx4 to [RAID 5] HDDx5
[RAID 0] HDDx4 to [RAID 5] HDDx6
[RAID 0] HDDx4 to [RAID 5] HDDx7
[RAID 0] HDDx4 to [RAID 5] HDDx8
[RAID 0] HDDx5 to [RAID 5] HDDx6
[RAID 0] HDDx5 to [RAID 5] HDDx7
[RAID 0] HDDx5 to [RAID 5] HDDx8
[RAID 0] HDDx6 to [RAID 5] HDDx7
[RAID 0] HDDx6 to [RAID 5] HDDx8
[RAID 0] HDDx7 to [RAID 5] HDDx8
X
RAID
1
[OFFLINE]
[RAID 1] HDDx2 to [RAID 0] HDDx2
[RAID 1] HDDx2 to [RAID 0] HDDx3
[RAID 1] HDDx2 to [RAID 0] HDDx4
[RAID 1] HDDx2 to [RAID 0] HDDx5
[RAID 1] HDDx2 to [RAID 0] HDDx6
[RAID 1] HDDx2 to [RAID 0] HDDx7
[RAID 1] HDDx2 to [RAID 0] HDDx8
[RAID 1] HDDx3 to [RAID 0] HDDx4
[RAID 1] HDDx3 to [RAID 0] HDDx5
[RAID 1] HDDx3 to [RAID 0] HDDx6
[RAID 1] HDDx3 to [RAID 0] HDDx7
[RAID 1] HDDx3 to [RAID 0] HDDx8
[RAID 1] HDDx4 to [RAID 0] HDDx5
[RAID 1] HDDx4 to [RAID 0] HDDx6
[RAID 1] HDDx4 to [RAID 0] HDDx7
[RAID 1] HDDx4 to [RAID 0] HDDx8
[RAID 1] HDDx5 to [RAID 0] HDDx6
[RAID 1] HDDx5 to [RAID 0] HDDx7
[RAID 1] HDDx5 to [RAID 0] HDDx8
[RAID 1] HDDx6 to [RAID 0] HDDx7
[ONLINE]
[RAID 1] HDDx2 to [RAID 5] HDDx3
[RAID 1] HDDx2 to [RAID 5] HDDx4
[RAID 1] HDDx2 to [RAID 5] HDDx5
[RAID 1] HDDx2 to [RAID 5] HDDx6
[RAID 1] HDDx2 to [RAID 5] HDDx7
[RAID 1] HDDx2 to [RAID 5] HDDx8
[RAID 1] HDDx3 to [RAID 5] HDDx4
[RAID 1] HDDx3 to [RAID 5] HDDx5
[RAID 1] HDDx3 to [RAID 5] HDDx6
[RAID 1] HDDx3 to [RAID 5] HDDx7
[RAID 1] HDDx3 to [RAID 5] HDDx8
[RAID 1] HDDx4 to [RAID 5] HDDx5
[RAID 1] HDDx4 to [RAID 5] HDDx6
[RAID 1] HDDx4 to [RAID 5] HDDx7
[RAID 1] HDDx4 to [RAID 5] HDDx8
[RAID 1] HDDx5 to [RAID 5] HDDx6
[RAID 1] HDDx5 to [RAID 5] HDDx7
[RAID 1] HDDx5 to [RAID 5] HDDx8
[RAID 1] HDDx6 to [RAID 5] HDDx7
[RAID 1] HDDx6 to [RAID 5] HDDx8
[ONLINE]
[RAID 1] HDDx2 to [RAID 6] HDDx4
[RAID 1] HDDx2 to [RAID 6] HDDx5
[RAID 1] HDDx2 to [RAID 6] HDDx6
[RAID 1] HDDx2 to [RAID 6] HDDx7
[RAID 1] HDDx2 to [RAID 6] HDDx8
[RAID 1] HDDx3 to [RAID 6] HDDx4
[RAID 1] HDDx3 to [RAID 6] HDDx5
[RAID 1] HDDx3 to [RAID 6] HDDx6
[RAID 1] HDDx3 to [RAID 6] HDDx7
[RAID 1] HDDx3 to [RAID 6] HDDx8
[RAID 1] HDDx4 to [RAID 6] HDDx5
[RAID 1] HDDx4 to [RAID 6] HDDx6
[RAID 1] HDDx4 to [RAID 6] HDDx7
[RAID 1] HDDx4 to [RAID 6] HDDx8
[RAID 1] HDDx5 to [RAID 6] HDDx6
[RAID 1] HDDx5 to [RAID 6] HDDx7
[RAID 1] HDDx5 to [RAID 6] HDDx8
[RAID 1] HDDx6 to [RAID 6] HDDx7
[RAID 1] HDDx6 to [RAID 6] HDDx8
[RAID 1] HDDx7 to [RAID 6] HDDx8
NOTE
The migr
ation scheme below
is based on Thecus
Thecus IP Storage series products in maximum
possible combination. The other model which has
less HDD supported can refer web UI while RAID
migration operated.