Since the interference affects both cores equally, by subtracting the phase-shifted signals, the
interfering signal is completely neutralized. The result is a pure signal without any noise inter-
ference.
1 Signal (in phase, +)
2 Signal (out of phase, –)
3 Ground
1 Signal (left)
2 Signal (right)
3 Ground, shielding
1/4" TRS phone plug (mono, bal-
anced)
Three-pole 1/8" mini phone jack
(stereo, unbalanced)
Plug and connection assignment
IEM-75