User manual
Table Of Contents
15 Power cord
16 [ON] [OFF] [STANDBY]
On / o switch for standby function. If the standby function is enabled, the device automatically switches to standby
mode after fteen minutes without any input signal.
17 [BREAKER]
Resettable fuse. The fuse switches o when the power consumption of the power amplier is too high. Once the
problem is resolved, the fuse is automatically reset and the device is ready for use again. The switch can be used to
force the reset.
18, 19 [OUTPUT]
Output channel B, A
n Speaker Twist chassis connector for speaker output (1+, 2+: positive; 1–, 2–: negative)
n Screw terminals
20, 22 [INPUT]
Input channel B, A
n XLR chassis socket
n ¼-inch (6.35-mm) jack (balanced or unbalanced)
Connections and operating elements
E-400, E-800, E-1200, E-1500