4.!INSTALLATION!INSTRUCTIONS!
!
/.,##>#?)$@%)>#&$,..,$>"#)
/ƚŝƐƚŚĞŝŶƐƚĂůůĞƌƐresponsibility!to!ensure!that!when!installing!the!appliance,!the!requirements! of!
the!Health!and!Safety!at!Work!Act!1974!are!met.!
The!installation!instructions!within!this!manual!provide!a!guide!for!safe!and!appropriate!installation,!
but! it! is! the! responsibility! of! the! installer! to! ensure! that! the! requirements! of! applicable! British!
Standards!are!met,!in!particular!BS!8303!and!BS!EN!15287:2007,!relating!to!the!installation!of!solid!
fuel!appliances.!
When!considering!the!installation!design,! ensure!appropriate!access!is!provided!for!cleaning!of!the!
appliance,!flue!pipe!and!chimney!flue.!This!appliance!is!suitable!for!intermittent!operation,!but!is!not!
suitable!for!use!in!a!shared!flue!system.!The!appliance!should!not! be!used!in!the!same!room!as!an!
extractor!fan,!as!this!can!cause!the!stove!to!emit!fumes!into!the!room.!
!
A%#$>.,$>"#)
ůů ƐƚŽǀĞƐ ƌĞƋƵŝƌĞ Ă ĐŽŶƐŝƐƚĞŶƚ ƐƵƉƉůLJ ŽĨ ĐŽŵďƵƐƚŝŽŶ Ăŝƌ ƚŽ Ăůůow! for! combustion! of! the! fire.!
Permanent!external!air!vents!are!required!for!stoves!with!a!nominal!output!of!greater!than!5kW.!
Document!J!of!the!Building!Regulations!explains!that!should!a!stove!be!installed!in!a!room!with!an!
air!permeability!of!lower!than!5.0m³/(h.m²),!a!permanent!external!air!vent!is!required,!irrespective!
of!the!nominal!output!of!the!stove.!!External!air!vents!must!be!positioned!so!they!are!not!liable!to!
be!blocked.!Based!upon!the!requirem ents! within!Document!J!of! the!Building! Regulations,!a! 5kW!
stove!has!the!below!air!vent!area!requirements.!
,9H)/6HM62N9593O)
MGUVQ(MWX)
+9:9MLM)29H)I6:3)2H62)V8MWX)
%&&%)YZZ)&6H96C)
>5.0!
11.0!
<5.0!
38.5!
!
Please!consult!Document!J!of!the! Building!Regulations!for!detailed!guidance,!particularly!for!new!
build!properties,!where!a!low!air!permeability!rating!may!necessitate!a!permanent!external!air!vent.!
! )
[()>#&$,..,$>"#)>#&$0*!$>"#&)