If rearrangement of the flue outlet connection is needed it must be
made before the stove is positioned in the fireplace.
Fig.7 500-Vista can be arranged for top or rear flue outlet.
500-Vista Stove rear flue connection conversion.
The stove is supplied ready for a top flue connection.
1. Unfasten the flue blanking plate.
2. Using the same bolts fasten either the optional Cast flue collar or Rear
flue box.
3. Open the stove door and remove the baffle.
4. Fit the top flue blanking plug and attach the flue blanking bar.
5. The stove is now ready for a rear flue connection.