Esse 105 Stove Instruction

23
The stove comes supplied with a steel rear heatshield This must be included in the installation. If
the stove is to be installed with a rear flue connection, the relevant section of the heatshield should
be removed. An optional additional heatshield can purchased, to reduce the distance to
combustibles.
Supplied heatshield
With rear flue knockout removed
CHIMNEY & FLUE
The stove must be installed and connected to the chimney and flue pipe in line with the current
requirements of Building Regulations. As a basic guideline, the chimney and flue installation should…
Have an internal cross section area of approximately 320c, with a minimum diameter
or square side length of 125mm².
Have a minimum height of 4.5m.
Be free from cracks, severe bends, voids and obstructions.
Ensure where a flue pipe connects to a chimney, the flue passes past the point where
the chimney narrows.
Ensure an appropriate flue draft, as detailed within the Flue Draft section of this
manual.
Take into consideration future access for maintenance and sweeping.
Please consult Document J of the Building Regulations for detailed guidance.
HEARTH
The hearth must be at least 12mm thick and of non-combustible material(s). When in use, the
temperature on the horizontal surface below the stove has been measured at <100°C. There must
be a minimum distance of 225mm from the front of the stove, to the front of the hearth. The hearth
must be of robust construction, capable of taking the weight of the stove. Please consult Document
J of the Building Regulations for detailed guidance.