PRODUCT SPECIFICATION – 100 SERIES
Key Product Specifications
ESSE 105
ESSE 155
Nominal Heat Output (Kw)
5.0
5.0
Weight (Kg)
85.3
81.7
Minimum Flue Draft
12Pa
12Pa
Flue Gas Mass Flow (g/s)
3.1
3.1
Flue temperature (°C)
244
244
Flue Diameter
5”
5”
Distance To Combustibles
Rear (mm)
Sides (mm)
With single wall flue & supplied
heatshield
600
600
With double wall flue &
optional additional heatshield
75
400
Distance To Non-Combustibles (Recommended)
Rear (mm)
Sides (mm)
All configurations
150
150 (75*)
* Minimum distance required, so as to accommodate the extension of the Bypass Boss, on right hand
side of the stove.
CO ALARM
Building regulations require that whenever a new or replacement fixed solid fuel or wood / biomass
appliance is installed in a dwelling, a carbon monoxide (CO) alarm must be fitted in the same room
as the appliance, in accordance with BS EN 50292:2002. Please consult Document J of the Building
Regulations for detailed guidance. The installation of an alarm must not be considered a substitute
for either installing the appliance correctly, or ensuring regular servicing and maintenance of the
appliance and chimney system.