PRODUCT SPECIFICATION 100 SERIES
Key Product Specifications
ESSE 105
ESSE 155
Nominal Heat Output (Kw)
5.0
5.0
Weight (Kg)
85.3
81.7
Minimum Flue Draft
12Pa
12Pa
Flue Gas Mass Flow (g/s)
3.1
3.1
Flue temperature (°C)
244
244
Flue Diameter
5”
5”
Distance To Combustibles
Rear (mm)
Sides (mm)
With single wall flue & supplied
heatshield
600
600
With double wall flue &
optional additional heatshield
75
400
Distance To Non-Combustibles (Recommended)
Rear (mm)
Sides (mm)
All configurations
150
150 (75*)
* Minimum distance required, so as to accommodate the extension of the Bypass Boss, on right hand
side of the stove.
CO ALARM
Building regulations require that whenever a new or replacement fixed solid fuel or wood / biomass
appliance is installed in a dwelling, a carbon monoxide (CO) alarm must be fitted in the same room
as the appliance, in accordance with BS EN 50292:2002. Please consult Document J of the Building
Regulations for detailed guidance. The installation of an alarm must not be considered a substitute
for either installing the appliance correctly, or ensuring regular servicing and maintenance of the
appliance and chimney system.