Data Sheet
DocID: 128512_128513_22.04.2021
Thomann GmbH • Hans-Thomann-Straße 1 • 96138 Burgebrach • Germany • www.thomann.de
Mic cable 2×0.22mm², 6mm Ø
Intended use
This device is used to transmit audio frequency signals. Any other use
or use under other operating conditions is considered to be improper
and may result in personal injury or property damage. No liability will
be assumed for damages resulting from improper use.
DANGER FOR CHILDREN
Ensure that plastic bags, packaging, etc. are properly disposed
of and are not in the reach of babies and young children. Chok-
ing hazard! Ensure that children do not detach any small parts
from the product. They could swallow the pieces and choke! Never let
children use electrical devices unattended.
PROTECT THE ENVIRONMENT
Disposal of the packaging material
For the transport and protective packaging, environmentally
friendly materials have been chosen that can be supplied to
normal recycling. Ensure that plastic bags, packaging, etc. are
properly disposed of. Do not just dispose these materials with your nor-
mal household waste, but make sure that they are fed to a recovery.
Please follow the notes and markings on the packaging.
Disposal of your old device
This product is subject to the European Waste Electrical and
Electronic Equipment Directive (WEEE) in its currently valid
version. Do not dispose of your old device with your normal
household waste. Dispose of this product through an ap-
proved waste disposal rm or through your local waste facility. Comply
with the rules and regulations that apply in your country. If in doubt,
consult your local waste disposal facility.
EN
Construction
1 Oxygen-free copper (OFC)
2 PVC
3 Cotton
4 Oxygen-free copper (OFC)
5 PVC
Technical specications
Conductor area 0.22mm² / AWG24
Composition of conductor 20 strands 0.12mm Ø | Annealed bare copper, 100% OFC
standard
Conductor insulation Soft and exible PVC
Conductor colour Blue, white or red
Composition of core 2 twisted conductors with cotton to make round
Copper winding 84 strands 0.10mm Ø | Annealed bare copper, 100% OFC
standard, Coverage ≥90%
Overall jacket material exible PVC
Overall jacket colour, surface characteristic, appearance black colour, not shiny, not sticky
Overall diameter 6.0mm
Conductor’max DC Resistance at 20°C 92.3Ω/km
Minimum insulating resistance at 70 0.015Ω/km