Installation Guide
4
Maintenance:
Indoor Installation
Maintenance:
Outdoor Installation
1. CARTRIDGE REPLACEMENT:
• Using an Allen Key, unthread Set Screw from handle
• Unthread and remove Dome Cap and Cartridge Nut.
• Remove and replace Cartridge. Use the 2 pins on
the bottom of the Cartridge to seat the Cartridge
correctly.
2. CHECK VALVE REPLACEMENT:
• Unthread Hose and Check Valve Housing.
• Remove and replace Check Valves by inserting them
O-Ring side forward into Check Valve Housing.
• Re-assemble.
3. AERATOR REPLACEMENT:
• Use Aerator Key to remove and replace Aerator.
4. AERATOR CLEANING:
• Clean aerator periodically to eliminate any build-up.
Aerator
Aerator
Locking Ring
Aerator Key
Cartridge
Dome Cap
Handle
Allen
Key
Set
Screw
Cartridge
Nut
Check Valve Housing
Hand Spray Supply Hose
O-Ring
Check Valve
Hand Spray Hose
1. CARTRIDGE REPLACEMENT:
• Using an Allen Key, unthread Set Screw from handle
• Unthread and remove Dome Cap and Cartridge Nut.
• Remove and replace Cartridge. Use the 2 pins on
the bottom of the Cartridge to seat the Cartridge
correctly.
2. CHECK VALVE REPLACEMENT:
• Unthread Hose and Check Valve Housing.
• Remove and replace Check Valves by inserting them
O-Ring side forward into Check Valve Housing.
• Re-assemble.
3. AERATOR REPLACEMENT:
• Use Aerator Key to remove and replace Aerator.
4. AERATOR CLEANING:
• Clean aerator periodically to eliminate any build-up.
Important - Your outdoor Galley BarTap
®
must be winterized
if temperature falls below freezing in your area.
5. WINTERIZE YOUR GALLEY BARTAP:
• Turn off water supply under the counter and disconnect
Hot and Cold Supply Hoses.
• Disconnect Check Valve Housing and Hand Spray
Supply Hose (see picture below); remove both Check
Valves.
• Open handle and pull out Hand Spray from spout to
drain any water; drain completely.