Installation Guide
1
1
Before You Begin Installation
Package Contents
Tools
1. Observe all local plumbing codes.
2. Turn off water supply.
3. Inspect water supplies for signs of damage. Replace if necessary.
4. DO NOT use petroleum-based products on this faucet.
INSTALLATION WARNING: NEVER USE TEFLON TAPE FOR OUT-OF-THE-WALL THREADED CONNECTIONS. USE
PROVIDED RUBBER GASKETS ONLY. NOT COMPLYING WITH THIS INSTRUCTION COULD DAMAGE THE PRODUCT
AND GENERATE LEAKAGE.
#2 & #3 PHILLIPS SCREWDRIVERS ADJUSTABLE WRENCH ADJUSTABLE PLIERS
Remove all contents from the package and
identify before installation.
1 - Aerator Key
2 - Faucet
3 - Optional Base Ring
4 - Stainless Steel Mounting Washer
5- Stainless Steel Mounting Nut with Two
Crosshead Screws
6- Counterweight with two rubber strips
Note: All Hoses come pre-installed into Faucet and
are water tested at the factory.
Recommended Pressure Range: 20PSI -
75PSI
Maximum Flow Rate: l.8GPM / 6.8L /min
Maximum Temperature: 150° F
Product is Certified to NSF/ ANSI 372 and conforms with
the lead content requirements for “lead free” plumbing as
e defined by California, Vermont, Maryland, and Louisiana
state laws and the U.S. Safe Drinking Water Act. This
faucet complies with ASME 112.18.1-2018/CSA B125.1-2018