User manual

1 Network ports on the rear panel of the rst unit.
2 [TERMINATE] pushbutton must not be pressed.
The LED above it is o.
3 Network ports on the rear panel of the last unit.
4 [TERMINATE] pushbutton must be pressed.
The LED above it is on.
The individual units are linearly linked via RJ45 network cables. Beginning and end of the net‐
work bus must be terminated. The beginning is terminated by a USB2CAND converter
(optional accessory, part no 440591). At the end, the [TERMINATE] switch must be pressed on
the rear panel of the last unit to enable the built-in terminating resistor for termination. The
[TERMINATE] switch on all units between the USB2CAND converter and the last device must
not be pressed.
Network setup and termination
Networking and remote control
line array element
30