User manual
Table Of Contents
3 Network ports on the rear panel of the last unit.
4 [TERMINATE] pushbutton must be pressed.
The LED above it is on.
The individual units must be linearly linked by RJ45 CAT5 cable. Beginning and end of the net‐
work bus must be terminated. The beginning is terminated by the CanBus converter. At the
end, the [TERMINATE] switch must be pressed on the rear panel of the last unit to enable the
built-in terminating resistor for termination. The [TERMINATE] switch on all units between the
CanBus converter and the last device must not be pressed.
Each device of a Pronet network must have a unique identier or ID. By default, the USB2CAN
converter has the ID 0. Any other device can only have an ID equal or higher than 1. There
must be no devices with the same ID on the network. The ID is assigned automatically when a
device connected to the network is turned on for the rst time.
Proceed as follows to assign a unique ID to all devices in the Pronet network:
1. Turn o all devices.
2. Connect them with the RJ-45 CAT5 cables in the desired order.
Network setup and termination
ID assignment
Networking and remote control
A 10 LA
33